RISE RESEARCH INSTITUTES OF SWEDEN ABBORÅSTED
Maskless aligner (MLA) / Laser Writer
The procurement includes a maskless aligner (MLA) / laser writer for patterning of semiconductor wafers and related substrates.
Laboratory Instruments
No credit card · Instant access
Content at a glance
- Tender type:
- Tender
- Contracting authority:
- RISE RESEARCH INSTITUTES OF SWEDEN AB
- Published:
- August 30, 2026
- Deadline:
- September 28, 2026
- Topic:
- Laboratory Instruments
Tender description
The procurement includes a maskless aligner (MLA) / laser writer for patterning of semiconductor wafers and related substrates.
Further details
With free access, documents, deadlines and submission notes are available in a structured format.
- Core requirements of the tender prioritized and prepared
- Deadlines, eligibility criteria and documents in one workflow
- Guidance for structured bid preparation
- Automatically discover matching follow-up tenders
30 days free · no credit card · cancel anytime
All procurement details
Buyer, lots, participants, locations, documents, and procedure data have already been captured. Open any area to see the complete information in your workspace.
4 data areas available
30 days free · no credit card · cancel anytime
Related tenders
9Deposition Tool 8 Inch
Freistaat Bayern vertreten durch die Technische Universität München, hier handelnd die Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II)GarchingDeadline: Oct 05The Technical University of Munich - Chair of Technical Physics E23/WMI will acquire a UHV cluster System for the fabrication of superconducting circuits on 8 inch'' wafers. The system must provide UHV conditions and has to include an HV load-lock chamber, a central handling chamber, a UHV chamber for the evaporation of Al thin films, a UHV chamber for sputtering of superconductors, a UHV chamber for oxidation, a UHV chamber for Ar ion milling, and a flipping station. The system must allow metalizing both sides of the wafers in situ, with minimal backside particle contamination. The wafers should only be touched on the side (edge gripping).A complete femtosecond laser and transient absorption system
Uppsala universitetUppsalaDeadline: Sep 28The procurement concerns one (1) complete femtosecond laser and transient absorption system, including pump laser, optical parametric amplifiers (OPAs), and a fully integrated transient absorption spectrometer platform. The system is intended to be used in two (2) separate experiments, one pumping in the visible-NIR and probing in the UV-Vis-NIR and the other pumping in the vis-NIR and probing in mid-IR, where we already have a detection system. The two (2) experiments will not be run simultaneously.RFI - 1105601 UiO Life Sciences user equipment. K970.01 Laser microdissection microscope for DVP
STATSBYGGOSLODeadline: Sep 30Statsbygg is constructing the new Life Sciences Building (LVB) for the University of Oslo and Oslo University Hospital, on behalf of the Norwegian Ministry of Education and Research, with the South-Eastern Norway Regional Health Authority as co-commissioning authority. The building will provide workplaces for approximately 1,600 employees and 1,600 students. Excavation and groundwork commenced in the second quarter of 2019, and completion is scheduled for the end of 2026. The building will bring together a range of academic and research disciplines in a joint interdisciplinary environment to develop new solutions to major challenges in health and sustainability, with access to the best and most modern equipment required to conduct world-class research, teaching and innovation.Flip Chip Die Bonder
FAIR - Facility for Antiproton and Ion Research in Europe GmbHDarmstadtDeadline: Sep 21Flip Chip Die Bonder In flip-chip assembly, a semiconductor chip is electrically connected directly underside to a sensor via contact bumps. This requires a flip-chip die bonder, which places the chips flipped on the sensors with micrometer precision and enables various bonding technologies such as soldering, thermal bonding, and conductive adhesive bonding. Flip Chip Die Bonder The Flip-chip Die bonder should include the following process modules: - Precision die bonding (face up) - Flip chip bonding (face down) - adapted system work table - chip and substrate heating with process gas enclosure - software-controlled bonding force module - ultrasonic bonding module - in-situ-monitoring with video camera - form generator for creating reference elements for face up alignment - tool tip changing module - three different tool tips - tool tip support including heater - dispenser module for paste and liquids - UV-curing module - die-eject moduleNTA equipment with Zeta potential
Fjársýsla ríkisinsReykjavíkDeadline: Sep 25Fjársýslan, on behalf of the University of Iceland, ID. No. 6001692039, invites tenders for 23402 – NTA equipment with Zeta potential. The purpose of this procurement is to acquire nanoparticle tracking analysis (NTA) instrument for research use at the University of Iceland. The scope of the contract includes the delivery of complete and fully operational NTA equipment, including all necessary accessories, hardware, software and services required for installation, operation and initial use.Lieferung und Installation von Ausrüstung für die APECS-Pilotlinie (Hochleistungsfemtosekundenlaser)
INL - INTERNATIONAL IBERIAN NANOTECHNOLOGY LABORATORYBragaThe subject matter of this contract is the supply and installation of scientific equipment and components to INL, listed below and detailed in Schedule V attached to these Standard Specifications (from now on referred to as ‘Specifications’). The equipment listed in Schedule V are the lots that the tender comprises. Tenderers may bid for one or more lots. The subject matter of the contract, in all cases, does not include so-called refurbished scientific instruments and equipment. The single lot comprising the tender is as follows: 1. High Power Femtosecond Laser The project is co-funded by the EU Chips Joint Undertaking under the Joint Procurement Agreement signed between INL and Chips JU.Elemental Analyzer-Isotope Ratio Mass Spectrometer (EA-IRMS) and entry-level Elemental Analyzer (EA)
University of JyväskyläJyväskylän yliopistoUniversity of Jyväskylä (JYU) is inviting tenders for an Elemental Analyzer-Isotope Ratio Mass Spectrometer (EA-IRMS) and for an entry-level Elemental Analyzer (EA) devices. EA-IRMS device shall be a fully automated single system for carbon, nitrogen, and sulphur analysis by flash combustion, and oxygen and hydrogen analysis by high temperature pyrolysis (reduction). The subject of the procurement is an EA-IRMS for the high-precision measurement of carbon (C), nitrogen (N), sulphur (S), oxygen (O) and hydrogen (H) isotope ratios (i.e., δ13C, δ15N, δ34S, δ18O and δ2H values) in solid environmental matrices. The device will primarily be used for the analysis of carbon, nitrogen, and sulphur. The instrument is to be optimized for continuous flow operation, but includes also a connection(s) for low flow peripherals. A separate Entry-level elemental analyzer (EA) for carbon, hydrogen and nitrogen (CHN) analysis of solid environmental matrices is also included in the procurement.LA3790C - FSI - CFT - Open (OJEU) Procedure for the Supply of an Automated Thermal Desorber Gas Chromatograph Mass Spectrometer (ATD-GCMS)
Education Procurement Service (EPS)LimerickDeadline: Sep 25Tenders are sought for the Supply, Delivery, Installation and Commissioning of an Automated Thermal Desorber coupled with a Gas Chromatograph Mass Spectrometry (ATD-GCMS) for the analysis of ignitable liquids in vapour samples. This will be an addition to the current ATD-GCMS in the Fires team of the Chemistry department to be able to deal with the volume of fire cases submitted to FSI. Materials submitted for analysis ignitable liquids include debris samples taken from a fire scene, clothing taken from suspects or victims, or any other solid sample where it is desired to determine whether or not there are ignitable liquids associated with it. Such samples are submitted to the Laboratory in sealed nylon bags. The customer need is for FSI to determine accurately, reliably and to an acceptable level of sensitivity whether or not such exhibits contain ignitable liquids.Microscale thermophoresis device
Oulun yliopistoOULUDeadline: Oct 09University of Oulu, Biocenter Oulu, seeks a spectral shift and microscale thermophoresis device to characterise qualitatively and determine quantitatively nanoparticle, including protein, interactions in the range of weak to tight binders in solution without immobilization (hereinafter referred to as the "device"). The device must enable the assessment of sample quality and aggregation and differentiating binding events from aggregation. The device will be used for analysis of interactions of fluorescence labelled proteins with small molecules and vesicles. The detection must be independent of the mass ratio of the binding partners. The device must enable fast screening of interactions as well as sensitive affinity measurement. The measurable dynamic range of dissociation constant must be at least in nM -mM range and binding affinity in at least nM -mM range. Low sample consumption (in order of 10 microlitre) and low nanomole of the labeled target is needed for the measurement. The device must enable detection of the interaction based on changes of emission spectrum of exited fluorophore under isothermal conditions and must be able to create a microscopic non-isothermal temperature field (temperature gradient) and determine nanoparticle including protein binding events based on the temperature related intensity change and fluorescence intensity change following thermophoresis under the thermal gradient. Intensity changes and/or spectrum shifts of the fluorescence probe versus ligand concentrations are measured and plotted to calculate the dissociation constant. The device must come with detailed documentation of all features. The device will be part of the Proteomics and protein analysis core facility infrastructure of Biocenter Oulu. The core facility has an open access policy, and the instrumentation and software must be easy to use and maintain. The device must include a user interface to control the operation. The device must be well suited to an academic multi-
Frequently asked questions about this tender
- How can I apply for this tender?
- Create a free account on Auftrag One. You will then see all documents, deadlines and submission notes in a structured workflow.
- What is the submission deadline?
- The submission deadline is 28. September 2026.
- Who is the contracting authority?
- The contracting authority is RISE RESEARCH INSTITUTES OF SWEDEN AB.
- Which documents are needed to get started?
- Typically you need the service description, proof of eligibility, deadline notes and possibly form sheets. On Auftrag One these items are displayed in prioritized order.