Photoluminescences is a versaille method for characterisation of direct semiconductors. In epitaxy typically whole wafers get PL-mapped to achive information on bandgap, uniformity, layer thickness or cavity dip. The desired tool is capable to measure in a spectral range from 800-2150nm, due to the (AlInGa)(AsP)-heterostructures which are...
Messtechnik, Laborinstrumente
Ohne Kreditkarte · Sofortiger Zugang
Inhalt auf einen Blick
- Ausschreibungstyp:
- Ausschreibung
- Auftraggeber:
- Fraunhofer-Gesellschaft zur Förderung der angewandten Forschung e.V. - Einkauf B12 - Vergabestelle Bau
- Veröffentlicht:
- 02. September 2026
- Frist:
- 05. Oktober 2026
- Thema:
- Messtechnik
Ausschreibungsbeschreibung
Vollständige Beschreibung anzeigenBeschreibung einklappen
Photoluminescences is a versaille method for characterisation of direct semiconductors. In epitaxy typically whole wafers get PL-mapped to achive information on bandgap, uniformity, layer thickness or cavity dip. The desired tool is capable to measure in a spectral range from 800-2150nm, due to the (AlInGa)(AsP)-heterostructures which are matter of investigations. The setup is capable of mapping entire 2 - 6 inch (50mm - 150mm) wafers. Options: 1. Excitation density tuning for Laser 1 (automized) 2. Laser 2 (DPSS) for InGaAs-contact bleach out for layers with thickness 50 - 200nm 3. Sample holder: Flexible sample positioning on entire chuck with vacuum clamping 4. Sample holder: Mount for DataRay BladeCam2
Weiterführende Details
Mit dem kostenlosen Zugang stehen Unterlagen, Fristen und Hinweise zur Einreichung strukturiert bereit.
- Kernanforderungen der Ausschreibung priorisiert aufbereitet
- Fristen, Eignungskriterien und Unterlagen in einem Ablauf
- Hinweise zur strukturierten Angebotsvorbereitung
- Passende Folgeausschreibungen automatisch entdecken
30 Tage kostenlos · keine Kreditkarte · jederzeit kündbar
Alle Vergabedetails
Auftraggeber, Lose, Beteiligte, Orte, Unterlagen und Verfahrensdaten sind bereits erfasst. Öffnen Sie einen Bereich, um die vollständigen Angaben im Workspace zu sehen.
6 Datenbereiche verfügbar
30 Tage kostenlos · keine Kreditkarte · jederzeit kündbar
Unterlagen
Freischalten50 Angaben erfasstUnterlagen · Dokumentenpaket
Auftraggeber
Freischalten6 Angaben erfasstAuftraggeber · Anschrift · Kontakt
Lose
Freischalten1 Angabe erfasstLose LOT-0000
Verfahrensdaten
Freischalten6 Angaben erfasstBekanntmachungsnummer · Verfahrensreferenz · Referenz des Auftraggebers · Verfahrensart · +2 weitere
Ausführungsorte
Freischalten2 Angaben erfasstAusführungsorte
Veröffentlichungsstelle
Freischalten6 Angaben erfasstVeröffentlichungsstelle · Anschrift · Kontakt
Ähnliche Bekanntmachungen
7Photolumineszenz-Mapper-NIR
Fraunhofer-Gesellschaft zur Förderung der angewandten Forschung e.V. - Einkauf B12 - Vergabestelle BauMünchenFrist: 05. Okt.Beschreibung: Photoluminescences is a versaille method for characterisation of direct semiconductors. In epitaxy typically whole wafers get PL-mapped to achive information on bandgap, uniformity, layer thickness or cavity dip. The desired tool is capable to measure in a spectral range from 800-2150nm, due to the (AlInGa)(AsP)-heterostructures which are matter of investigations. The setup is capable of mapping entire 2 - 6 inch (50mm - 150mm) wafers. Options: 1. Excitation density tuning for Laser 1 (automized) 2. Laser 2 (DPSS) for InGaAs-contact bleach out for layers with thickness 50 - 200nm 3. Sample holder: Flexible sample positioning on entire chuck with vacuum clamping 4. Sample holder: Mount for DataRay BladeCam2Solar Simulator
Freistaat Bayern, vertreten durch die Friedrich-Alexander-Universität Erlangen-NürnbergErlangenThis call for bids concerns the supply of a solar simulator that produces the solar spectrum for applications in photoelectrochemistry, photocatalysis, and photovoltaic research. The system must be capable of both standalone operation and integration with a scanning probe microscope via a fiber optic coupling. The solar simulator must enable controlled photo-irradiation of samples from multiple directions (with respect to the samples), including top, lateral, and bottom illumination. This capability is required to support a wide range of experimental configurations.Maskless aligner (MLA) / Laser Writer
RISE RESEARCH INSTITUTES OF SWEDEN ABBORÅSFrist: 28. Sept.The procurement includes a maskless aligner (MLA) / laser writer for patterning of semiconductor wafers and related substrates.LA3790C - FSI - CFT - Open (OJEU) Procedure for the Supply of an Automated Thermal Desorber Gas Chromatograph Mass Spectrometer (ATD-GCMS)
Education Procurement Service (EPS)LimerickFrist: 25. Sept.Tenders are sought for the Supply, Delivery, Installation and Commissioning of an Automated Thermal Desorber coupled with a Gas Chromatograph Mass Spectrometry (ATD-GCMS) for the analysis of ignitable liquids in vapour samples. This will be an addition to the current ATD-GCMS in the Fires team of the Chemistry department to be able to deal with the volume of fire cases submitted to FSI. Materials submitted for analysis ignitable liquids include debris samples taken from a fire scene, clothing taken from suspects or victims, or any other solid sample where it is desired to determine whether or not there are ignitable liquids associated with it. Such samples are submitted to the Laboratory in sealed nylon bags. The customer need is for FSI to determine accurately, reliably and to an acceptable level of sensitivity whether or not such exhibits contain ignitable liquids.Agnostic Slide scanner with integrated spectral unmixing
Kungliga Tekniska högskolanSTOCKHOLMFrist: 05. Okt.The purpose of this purchase is to acquire a slide scanner capable of imaging and detecting signals in both brightfield and fluorescence. The system will be used daily for scanning tissue sections on microscope slides and must support flexible marker detection across multiple wavelengths, with sensitive autofocus suitable for different tissue types. Due to extensive use, the scanner must be fast, reliable, and capable of continuous operation over long working hours.Deposition Tool 8 Inch
Freistaat Bayern vertreten durch die Technische Universität München, hier handelnd die Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II)GarchingFrist: 05. Okt.The Technical University of Munich - Chair of Technical Physics E23/WMI will acquire a UHV cluster System for the fabrication of superconducting circuits on 8 inch'' wafers. The system must provide UHV conditions and has to include an HV load-lock chamber, a central handling chamber, a UHV chamber for the evaporation of Al thin films, a UHV chamber for sputtering of superconductors, a UHV chamber for oxidation, a UHV chamber for Ar ion milling, and a flipping station. The system must allow metalizing both sides of the wafers in situ, with minimal backside particle contamination. The wafers should only be touched on the side (edge gripping).WaveMaster 8160HD Oszilloskop - PR1262783-2660-W
Fraunhofer-Gesellschaft zur Förderung der angewandten Forschung e.V. - Einkauf B12 - Vergabestelle BauMünchen2x WaveMaster 8160HD Oszilloskop IOF wants to procure 2 real-time oscilloscope wiht a bandwidth of 16 GHz and sampling rate of 80 GS/s over all 4 channels with 12 bit vertical resolution. The high vertical resolution and bandwidth is critical for our quantum experiments.
Häufige Fragen zu dieser Ausschreibung
- Wie kann ich mich auf diese Ausschreibung bewerben?
- Erstellen Sie ein kostenloses Konto auf Auftrag One. Danach sehen Sie alle Unterlagen, Fristen und Hinweise zur Einreichung in einem strukturierten Ablauf.
- Bis wann läuft die Angebotsfrist?
- Die Angebotsfrist endet am 05. Oktober 2026.
- Wer ist der Auftraggeber?
- Der Auftraggeber ist Fraunhofer-Gesellschaft zur Förderung der angewandten Forschung e.V. - Einkauf B12 - Vergabestelle Bau.
- Welche Unterlagen sind für den Start relevant?
- In der Regel benötigen Sie Leistungsbeschreibung, Eignungsnachweise, Fristenhinweise und ggf. Formblätter. Auf Auftrag One werden diese Punkte priorisiert dargestellt.