Danmarks Tekniske Universitet - DTUKgs. LyngbyTED
Scanning Electron Microscope
This tender concerns the acquisition of a scanning electron microscope (SEM) for a university facility that provides access to an extensive suite of nanofabrication and characterisation tools as one of its core purposes. Due to a recently identified bottleneck in the suite of high-end characterisation in the cleanroom, DTU wishes to acqui...
Laborinstrumente
Ohne Kreditkarte · Sofortiger Zugang
Inhalt auf einen Blick
- Ausschreibungstyp:
- Ausschreibung
- Auftraggeber:
- Danmarks Tekniske Universitet - DTU
- Veröffentlicht:
- 25. Juni 2026
- Frist:
- 31. August 2026
- Thema:
- Laborinstrumente
Ausschreibungsbeschreibung
Vollständige Beschreibung anzeigenBeschreibung einklappen
This tender concerns the acquisition of a scanning electron microscope (SEM) for a university facility that provides access to an extensive suite of nanofabrication and characterisation tools as one of its core purposes. Due to a recently identified bottleneck in the suite of high-end characterisation in the cleanroom, DTU wishes to acquire a SEM. This problem has arisen as the result of multiple breakdowns among the aging and current instruments thus exposing an unexpected vulnerability in the overall process flow of several of our commercial users. The instrument is intended to meet the characterization requirements of DTU’s key commercial customers. Accordingly, only a high-end system equipped with a field emission source, capable of delivering high emission at low energy spread, will be considered acceptable. The system must provide state-of-the-art lateral image resolution of 0.8 nm or better at an accelerating voltage of 15 kV, and 0.9 nm or better at 1 kV, both achieved without beam deceleration or sample bias and using the in-column secondary electron detector. The SEM must be compatible with samples originating directly from customer production processes and must therefore be capable of handling wafers with diameters of up to 200 mm. Typical substrate materials include silicon, fused silica, and quartz. These materials cannot be coated to reduce charging effects during SEM analysis, and the instrument must therefore be capable of imaging such non-conductive samples without the application of conductive coatings.
Weiterführende Details
Mit dem kostenlosen Zugang stehen Unterlagen, Fristen und Hinweise zur Einreichung strukturiert bereit.
- Kernanforderungen der Ausschreibung priorisiert aufbereitet
- Fristen, Eignungskriterien und Unterlagen in einem Ablauf
- Hinweise zur strukturierten Angebotsvorbereitung
- Passende Folgeausschreibungen automatisch entdecken
30 Tage kostenlos · keine Kreditkarte · jederzeit kündbar
Alle Vergabedetails
Auftraggeber, Lose, Beteiligte, Orte, Unterlagen und Verfahrensdaten sind bereits erfasst. Öffnen Sie einen Bereich, um die vollständigen Angaben im Workspace zu sehen.
7 Datenbereiche verfügbar
30 Tage kostenlos · keine Kreditkarte · jederzeit kündbar
Unterlagen
Freischalten50 Angaben erfasstUnterlagen · Dokumentenpaket
Auftraggeber
Freischalten3 Angaben erfasstAuftraggeber · Anschrift · Kontakt
Lose
Freischalten1 Angabe erfasstLose LOT-0000
Verfahrensdaten
Freischalten5 Angaben erfasstBekanntmachungsnummer · Verfahrensreferenz · Verfahrensart · Auftragsart · +1 weitere
Ausführungsorte
Freischalten3 Angaben erfasstAusführungsorte
Bieter und Auftragnehmer
Freischalten3 Angaben erfasstBieter und Auftragnehmer · Anschrift · Kontakt
Veröffentlichungsstelle
Freischalten6 Angaben erfasstVeröffentlichungsstelle · Anschrift · Kontakt
Ähnliche Bekanntmachungen
7Focused Ion Beam, Scanning Electron Microscope (FIB-SEM)
Lunds universitetLundFrist: 24. Aug.Lund Nano Lab (LNL) at Lund University intends to purchase a Focused Ion Beam Scanning Electron Microscope, in this document referred to as the FIB-SEM, instrument or equipment. This document lists all the requirements the FIB-SEM must meet. The instrument is intended to be used for high-resolution imaging, materials analysis and preparing samples for TEM analysis as well as for experiments at the MAX IV synchrotron.High-resolution Scanning electron microscope (SEM)
Tampere University Foundation srTampereFrist: 04. Sept.Tampere University Foundation sr is inviting tenders for 'High-resolution Scanning electron microscope (SEM)', hereinafter also as 'SEM'.Market consultation advanced inverted fluorescence microscope
Rijksuniversiteit GroningenGroningenFrist: 30. JuliIntroduction Within the University of Groningen (UG), at the Groningen Research Institute of Pharmacy, the Pharmaceutical Analysis Group studies cell behaviour and nanoparticle dynamics in physiologically relevant microenvironments, with a particular focus on microfluidic devices and hydrogel-based platforms. A central aspect of this research is the ability to engineer precisely defined biochemical and physical microenvironments at the sub-micron scale, and to observe how cells and particles respond to these environments over time. To address the research questions arising in this context, an advanced inverted fluorescence microscope is required, capable of supporting both high-precision imaging and laser patterning of microenvironments, long-term live imaging of dim fluorescent samples across extended timescales of 24 hours or more, and real-time closed-loop experiment control, where imaging data must be processed and acted upon during acquisition rather than after the fact. To enable sub-micron laser photopatterning, the microscope must support stable and validated integration with the Alveole Primo2 system, a laser-based photopatterning module which will be available in the group. Together, these requirements place stringent demands on the optical performance, mechanical stability, and computational capabilities of the microscope. Please see the market consultation document for further information.Slide Scanning Microscope
Royal College of Surgeons in Ireland_362DublinFrist: 13. JuliA slide scanning microscope for high throughput brightlight and fluorescence microscopy in a research laboratory setting.European Tender Electron Beam Lithography system
Universiteit TwenteEnschedeFrist: 21. Aug.The University of Twente is tendering to purchase an Electron Beam Lithography system. The MESA+ Institute of the University of Twente will invest in a new Electron Beam system (e-beam system). A system, suitable for defining patterns in electron sensitive resists, at high resolution and high speed, compatible with a wide range of applications and substrate types up to 200mm in diameter. The system will be used by a wide range of users, i.e. academic researchers and students as well as industrial engineers with different backgrounds (photonics, (nano)-electronics etc.) and different levels of expertise.Raman Microscope for DTU Chemistry
Danmarks Tekniske Universitet - DTUKgs. LyngbyThe Technical University of Denmark (DTU) intends to acquire one complete high-resolution confocal Raman microscopy and spectroelectrochemical characterization system, including all associated hardware, software, accessories, installation, commissioning, training, and warranty. The system will support research and education activities within catalysis, electrochemistry, materials science, energy conversion, sustainable fuels, and chemical synthesis. The primary purpose is to enable advanced in situ and operando characterization of functional materials, catalyst surfaces, and catalytic interfaces under realistic operating conditions, including electrochemical environments, elevated temperatures, controlled gas atmospheres, liquid-phase operation, and flow conditions. The instrument shall provide high-sensitivity Raman spectroscopy and microscopy with high spectral and spatial resolution. The system must support characterization of solids, liquids, heterogeneous materials, catalyst surfaces, thin films, nanostructured materials, powders, and solid–liquid and solid–gas interfaces. The equipment shall further enable investigation of reaction intermediates, catalyst transformations, phase transitions, adsorbates, reaction microenvironments, and dynamic processes occurring during electrochemical and catalytic reactions. The system shall include a confocal Raman microscope with automated operation, high-resolution spectroscopic capabilities, motorized sample positioning, automated focusing, Raman mapping and imaging functionality, and support for multiple excitation wavelengths covering the visible and near infrared spectral range, including excitation wavelengths of approximately 532 nm, 633 nm, and 785 nm. The system must be capable of performing both point measurements and spatially resolved Raman imaging of heterogeneous samples with automated data acquisition. The acquisition shall include low-noise detector technology suitable for weak Raman signals, time resolved measurements, and quantitative analysis of both Stokes and anti-Stokes Raman scattering. The system shall provide access to ultra-low-frequency vibrational information (down to 10 cm-1) relevant for studying structural changes, lattice dynamics, catalyst phase transformations, interfacial species, adsorption phenomena, and local temperature effects at catalytic interfaces. The instrument shall further enable simultaneous investigation of chemical composition, structural dynamics, and local thermal phenomena under operating conditions through acquisition of both Stokes and anti-Stokes Raman spectra. The system shall support automated Raman mapping and hyperspectral imaging of heterogeneous samples with micrometre-scale spatial resolution and high positional accuracy. The system must enable investigation of catalyst heterogeneity, dynamic restructuring processes, spatial distributions of reaction intermediates, and structure–activity relationships during operation. The system shall support time-resolved and operando measurements through direct integration be-tween electrochemical instrumentation and the spectroscopic platform, enabling synchronized electrochemical control and Raman data acquisition. The system shall allow simultaneous monitoring of electrochemical parameters and spectroscopic responses during catalytic operation and provide direct correlation between catalyst state, reaction intermediates, local temperature, and electrochemical performance. The equipment shall be suitable for spectroelectrochemical investigations of electro-chemical reactions and interfaces under controlled operating conditions. The acquisition shall further include dedicated spectroelectrochemical accessories, electrochemical cells suitable for operando measurements, flow-compatible accessories, control software, data acquisition and processing software, computer workstation, vibration-isolated installation platform, and all components necessary for full operation of the instrument. The system shall be designed for long-term research use and support future expansion through additional optical components, detectors, excitation sources, analytical modules, environmental cells, and experimental accessories. Scope of supply: • One complete confocal Raman spectroscopy and microscopy system. • High-resolution spectrometer and detector system. • Multiple excitation wavelengths. • Automated sample positioning, focusing, and mapping capabilities. • Raman imaging and hyperspectral mapping functionality. • Ultra-low-frequency Raman measurement capability. • Stokes and anti-Stokes Raman measurement capability. • Integrated spectroelectrochemical measurement capability. • Electrochemical cell and associated accessories for operando measurements. • Instrument control, acquisition, synchronization, analysis, and visualization software. • Computer workstation and control electronics. • Optical table or equivalent vibration-isolated installation platform. • Installation, commissioning, training, documentation, and warranty. Quantity: One complete integrated Raman microscopy and spectroelectrochemical characterization system.High-speed High-resolution Spinning-disk Confocal Microscope for live cell and fixed samples
University of HelsinkiUniversity of HelsinkiFrist: 20. Aug.We ask tenders for an advanced spinning-disk confocal microscopy system (High-speed High-resolution Spinning-disk Confocal Microscope for live cell and fixed samples). Instrumentation will be acquired to the Biomedicum Imaging Unit, imaging core facility within the University of Helsinki. Maximum price of system is 450 000 € (VAT 0 %), including shipping, installation, user training, and insurance until final acceptance of instrument. System must be delivered and installed within 14 weeks from purchase order date. In addition, we ask annual preventative maintenance contract for total 5 years after warranty period as an option. Price per year after warranty period shall be indicated and total price over five years given (for the evaluation). The buyer reserves the right to decide at the end of each yearly period whether to accept the option of continuing the service contract for another year (up to maximum five years) at tendered price.
Häufige Fragen zu dieser Ausschreibung
- Wie kann ich mich auf diese Ausschreibung bewerben?
- Erstellen Sie ein kostenloses Konto auf Auftrag One. Danach sehen Sie alle Unterlagen, Fristen und Hinweise zur Einreichung in einem strukturierten Ablauf.
- Bis wann läuft die Angebotsfrist?
- Die Angebotsfrist endet am 31. August 2026.
- Wer ist der Auftraggeber?
- Der Auftraggeber ist Danmarks Tekniske Universitet - DTU.
- Welche Unterlagen sind für den Start relevant?
- In der Regel benötigen Sie Leistungsbeschreibung, Eignungsnachweise, Fristenhinweise und ggf. Formblätter. Auf Auftrag One werden diese Punkte priorisiert dargestellt.