Aalborg UniversitetAalborg ØstTED
ImageXpress HCS.AI Advanced System
The system will provide researchers from various research groups with a microscopy solution suitable for a wide range of current and future experimental applications. These include high-content screening of pharmacological and biological perturbations across a range of sample carriers (including microscope slides, multiwell plate formats,...
Messtechnik, Laborinstrumente
Ohne Kreditkarte · Sofortiger Zugang
Inhalt auf einen Blick
- Ausschreibungstyp:
- Ausschreibung
- Auftraggeber:
- Aalborg Universitet
- Veröffentlicht:
- 08. Juli 2026
- Frist:
- Nicht angegeben
- Thema:
- Messtechnik
Ausschreibungsbeschreibung
Vollständige Beschreibung anzeigenBeschreibung einklappen
The system will provide researchers from various research groups with a microscopy solution suitable for a wide range of current and future experimental applications. These include high-content screening of pharmacological and biological perturbations across a range of sample carriers (including microscope slides, multiwell plate formats, and specialized geometries such as U-shaped plates), quantitative analysis of physiologically relevant 3D models (including tissue samples, spheroids, and organoids), and imaging of complex co-culture systems requiring multi-compartment or insert-based configurations. Uniqueness statement: The described procurement concerns a highly specialized high-content confocal imaging system required to support advanced, large-scale biological experiments within a shared research infrastructure. The requirements define a tightly integrated combination of functionalities, including: • High-throughput plate-based acquisition of multiwell experiments (96-384 well formats) within defined time constraints, with full plate acquisition achievable in the order of 1-5 minutes for single-position imaging and ≤30-60 minutes under realistic screening conditions, including multiple imaging positions per well (≥9), multi-channel fluorescence acquisition (≥3 channels), and Z-stack acquisition (≥20 planes). Full 96-well plate confocal imaging (≥3 channels, ≥20x objective) must be achievable within ≤10 minutes at one position per well. • Confocal optical sectioning for imaging of thick 3D biological samples, with effective penetration and signal quality for structures in the range of 50-200 um (up to ~300 um depending on sample type). For this, the imaging system must be able to operate in both widefield and spinning disk confocal modes. Availability of a minimum of two (2) confocal spinning disc geometries under software control, with options optimized for different applications, such as high-resolution, high-speed, and deep-penetration imaging, with the option for future disc upgrades. • Low phototoxicity and low photobleaching imaging conditions, enabling repeated imaging of the same samples for time-lapse experiments over hours to days, including sensitive 3D cultures and live-cell assays. • High-power laser excitation (up to 800 mW) combined with a motorized XY-stage and Z control with high-precision positioning (<25 nm resolution in all axes) and the stability required for reliable time-lapse imaging of the same sites over several hours or days is needed. • A software-controlled, automated objective turret with at least six (6) positions, equipped with a range of air and water immersion objectives from 2x to 60x magnification that includes options for both high numerical aperture (NA) and extra-long working distance. The system must be equipped with a fully automated water immersion objective system with 20x and 40x water immersion objectives, and support optional magnification changes via an additional, software-selectable tube lens (1.5x). • Independent emission filter wheel (≥8 positions) and dichroic filter wheel (≥4 positions), equipped with filter sets for imaging DAPI, CFP, FITC, YFP, TRITC, TxRed, Cy5, and Cy7, or their equivalents. • Fully automated, high-content acquisition workflows, enabling reproducible imaging of large datasets (≥100-1000 imaging sites per experiment) with minimal user intervention. • A high-sensitivity sCMOS camera with high peak quantum efficiency (≥95%). The system is required to support high-speed image streaming for dynamic live-cell assays such as calcium imaging. The requirement is acquisition at ≥80 fps at full resolution and ≥100 fps at reduced resolution (using binning). • Integrated environmental control for physiologically relevant experiments with integrated gasmixer in the system for precise control of CO2 and O2 levels to create both normal and hypoxic conditions. • Integrated, high-throughput image analysis capabilities, including automated segmentation, feature extraction, and compatibility with AI machine learning-based analysis pipelines, enabling efficient processing and quantification of large-scale datasets. Possibility of importing images from 3rd party instruments for analysis is required. These requirements are not independent, but must be fulfilled simultaneously within a single, unified system architecture to ensure technical suitability, data quality, and operational feasibility. While individual elements of the required functionality may be available in other systems, available alternatives do not provide the full combination of required capabilities within a single, fully integrated high-content screening platform. In practice, alternative solutions rely on partial, modular, or loosely integrated configurations, where acquisition, automation, and analysis are handled by separate components or software environments. This prevents consistent, reproducible execution of large-scale experiments and introduces technical limitations in throughput, data consistency, and workflow integration. The ImageXpress HCS.AI Advanced platform is identified as the only system available that meets all specified requirements as an integrated solution. No alternative suppliers can deliver a technically equivalent system without introducing significant limitations that render the solution unsuitable for the intended research applications. Consequently, the procurement is considered to fall under a situation where competition is absent for technical reasons, as only one supplier can deliver a system that fulfils the defined requirements.
Weiterführende Details
Mit dem kostenlosen Zugang stehen Unterlagen, Fristen und Hinweise zur Einreichung strukturiert bereit.
- Kernanforderungen der Ausschreibung priorisiert aufbereitet
- Fristen, Eignungskriterien und Unterlagen in einem Ablauf
- Hinweise zur strukturierten Angebotsvorbereitung
- Passende Folgeausschreibungen automatisch entdecken
30 Tage kostenlos · keine Kreditkarte · jederzeit kündbar
Alle Vergabedetails
Auftraggeber, Lose, Beteiligte, Orte, Unterlagen und Verfahrensdaten sind bereits erfasst. Öffnen Sie einen Bereich, um die vollständigen Angaben im Workspace zu sehen.
7 Datenbereiche verfügbar
30 Tage kostenlos · keine Kreditkarte · jederzeit kündbar
Unterlagen
Freischalten50 Angaben erfasstUnterlagen · Dokumentenpaket
Auftraggeber
Freischalten3 Angaben erfasstAuftraggeber · Anschrift · Kontakt
Lose
Freischalten1 Angabe erfasstLose LOT-0000
Verfahrensdaten
Freischalten6 Angaben erfasstBekanntmachungsnummer · Verfahrensreferenz · Referenz des Auftraggebers · Verfahrensart · +2 weitere
Ausführungsorte
Freischalten3 Angaben erfasstAusführungsorte
Bieter und Auftragnehmer
Freischalten2 Angaben erfasstBieter und Auftragnehmer · Anschrift
Veröffentlichungsstelle
Freischalten3 Angaben erfasstVeröffentlichungsstelle · Anschrift · Kontakt
Ähnliche Bekanntmachungen
9Market consultation advanced inverted fluorescence microscope
Rijksuniversiteit GroningenGroningenFrist: 30. JuliIntroduction Within the University of Groningen (UG), at the Groningen Research Institute of Pharmacy, the Pharmaceutical Analysis Group studies cell behaviour and nanoparticle dynamics in physiologically relevant microenvironments, with a particular focus on microfluidic devices and hydrogel-based platforms. A central aspect of this research is the ability to engineer precisely defined biochemical and physical microenvironments at the sub-micron scale, and to observe how cells and particles respond to these environments over time. To address the research questions arising in this context, an advanced inverted fluorescence microscope is required, capable of supporting both high-precision imaging and laser patterning of microenvironments, long-term live imaging of dim fluorescent samples across extended timescales of 24 hours or more, and real-time closed-loop experiment control, where imaging data must be processed and acted upon during acquisition rather than after the fact. To enable sub-micron laser photopatterning, the microscope must support stable and validated integration with the Alveole Primo2 system, a laser-based photopatterning module which will be available in the group. Together, these requirements place stringent demands on the optical performance, mechanical stability, and computational capabilities of the microscope. Please see the market consultation document for further information.Market consultation advanced maskless photopatterning system
Rijksuniversiteit GroningenGroningenFrist: 26. JuliIntroduction Within the University of Groningen (UG), at the Groningen Research Institute of Pharmacy, the Pharmaceutical Analysis Group studies cell behaviour in physiologically relevant microenvironments, with a particular focus on microfluidic devices and hydrogel-based platforms. A central aspect of this research is the ability to engineer precisely defined biochemical and physical microenvironments at the sub-micron scale, in which cells can then be imaged and observed over time. To address the research questions arising in this context, an advanced maskless photopatterning system is required, capable of three functions within a single device: micropatterning of biomolecules for defining regions where cell can adhere, three-dimensional structuration of UV-sensitive hydrogels for structuring the mechanical environments of the cells, and microfabrication of microfluidic channels for enabling control of the biochemical environment of the cells. These three functions must be reconfigurable on demand and in real time, and the system must mount on an inverted fluorescence microscope, so that patterning can be performed at precisely imaged locations and in closed loop with observed cell behaviour. Together, these requirements place stringent demands on the patterning resolution, design flexibility, multi-function capability, and microscope integration of the instrument. See the market consultation document for futher information.European Tender Electron Beam Lithography system
Universiteit TwenteEnschedeFrist: 21. Aug.The University of Twente is tendering to purchase an Electron Beam Lithography system. The MESA+ Institute of the University of Twente will invest in a new Electron Beam system (e-beam system). A system, suitable for defining patterns in electron sensitive resists, at high resolution and high speed, compatible with a wide range of applications and substrate types up to 200mm in diameter. The system will be used by a wide range of users, i.e. academic researchers and students as well as industrial engineers with different backgrounds (photonics, (nano)-electronics etc.) and different levels of expertise.Service Contract for ImageXpress HCS.ai Advanced
BraunschweigService Contract for ImageXpress HCS.ai Advanced Servicvertrag Service Contract for ImageXpress HCS.ai AdvancedSOC Test System
Fraunhofer-Gesellschaft, Einkauf B12MünchenBeschreibung: This specification describes the requirements for a semiconductor test system (mixed-signal test system) to be used for post-silicon verification, characterization and functional test of integrated circuits and chiplets at Fraunhofer EMFT. The test system must provide interfaces that allow connection with an industrial standard wafer probing system as well as with an industrial standard device handling system. The test system has to be compatible in Hard- and Software to an already existing Advantest V93000 test system in the Fraunhofer-Gesellschaft. With Option 1: an extended warranty contract Option 2: a service contract Option 3: A maintanance support contractMarket Consultation Hyperspectral Raman Imaging System
Wageningen University & ResearchWageningenFrist: 06. Aug.At the WUR as Contracting Authority, the procurement need has arisen to enter into a new Contract for a Push Broom Hyperspectral Imaging System for Inline Scan Raman Imaging at 785 nm Excitation. Prior to the tender, we would like to get a better understanding and representation of possible market parties, available technologies, and estimated budgets.Upgrade SAXS System
Institute of Science and Technology Austria (ISTA)KlosterneuburgUpgrade of a small angle X-ray scattering (SAXS) with Metal Jet source and a wide-angle detector - The first upgrade is installation of additional, stronger (higher flux) source in order to allow for high resolution small-angle measurements, in order to elucidate unambiguously determine structure of nanoparticle assemblies. The second upgrade is with additional wide-angle X-ray scattering (WAXS) detector in order to allow, in combination with current detector, for simultaneous measurement of short-range (atomic level) and long-range order.Learning Management System for European Raw Materials Academy and European Advanced Materials Academy
EIT RawMaterials GmbHBerlinFrist: 22. Sept.The procurement concerns the provision, implementation and hosting of a scalable, cloud-based Learning Management System for EIT RawMaterials, including course delivery, learner management and reporting, certification, and integration with the central course catalogue. For further details reference is made to the service description.High resolution nano-XCT system
Fraunhofer-Gesellschaft zur Förderung der angewandten Forschung e.V. | IMWS vertreten durch: Fraunhofer-Institut für Mikrostruktur von Werkstoffen und Systemen IMWSHalle (Saale)Frist: 04. Sept.The Fraunhofer Institute for Microstructure of Materials and Systems IMWS researches the application behaviour, reliability, safety and lifetime of innovative materials in components and systems. The Business Unit “Electronic Materials and Components” Fraunhofer IMWS support industry and research partners by its internationally recognized expertise in failure analyses of electronic components. Fraunhofer IMWS will enhance its capabilities for advanced failure analysis and material characterization to support the ramp up of new heterogenous integration technologies addressing the manufacturing and reliability challenges. To enable the non-destructive detection and evaluation of structural deviations, contact defects, damage characteristics and their most precise possible localization in the package to enable further high-resolution physical diagnostics, the latest generation of radiography (2D) and X-ray tomography (3D-CT) systems are required in particular for the non-destructive detection and evaluation of structural deviations, contact defects, damage characteristics and their most precise possible localization in the package to enable further high-resolution physical diagnostics. A high-performance multi-processor workstation is required for postprocessing of the generated imaging data sets to identify tiny deviations and defects within the devices. This tender is for the supply a functional complete device including assembly, commissioning and all necessary connections, approvals/certifications and software for operation. The requirements for a state-of-the-art x-ray inspection tool for highly integrated 2.5/3D components are described below:
Häufige Fragen zu dieser Ausschreibung
- Wie kann ich mich auf diese Ausschreibung bewerben?
- Erstellen Sie ein kostenloses Konto auf Auftrag One. Danach sehen Sie alle Unterlagen, Fristen und Hinweise zur Einreichung in einem strukturierten Ablauf.
- Bis wann läuft die Angebotsfrist?
- Für diese Bekanntmachung ist aktuell keine konkrete Angebotsfrist angegeben.
- Wer ist der Auftraggeber?
- Der Auftraggeber ist Aalborg Universitet.
- Welche Unterlagen sind für den Start relevant?
- In der Regel benötigen Sie Leistungsbeschreibung, Eignungsnachweise, Fristenhinweise und ggf. Formblätter. Auf Auftrag One werden diese Punkte priorisiert dargestellt.