Energinet Eltransmission A/SFredericiaTED
220/132 kV Autotransformers for SLF02
Delivery of three (3) 500 MVA, 220/132 kV autotransformers for substations for out-door installation. Rated power: 500 MVA Rated voltage Ur: 220/132 kV Max. operating voltage Umax: 245 kV Frequency: 50 Hz Cooling: ONAN/ONAF Corrosion Protection: C5VH or above Maximum sound power level: 92 dB(A), preferably lower, (at rated voltage 220/132...
Netzinfrastruktur
Ohne Kreditkarte · Sofortiger Zugang
Inhalt auf einen Blick
- Ausschreibungstyp:
- Ausschreibung
- Auftraggeber:
- Energinet Eltransmission A/S
- Veröffentlicht:
- 09. August 2026
- Frist:
- Nicht angegeben
- Thema:
- Netzinfrastruktur
Ausschreibungsbeschreibung
Delivery of three (3) 500 MVA, 220/132 kV autotransformers for substations for out-door installation. Rated power: 500 MVA Rated voltage Ur: 220/132 kV Max. operating voltage Umax: 245 kV Frequency: 50 Hz Cooling: ONAN/ONAF Corrosion Protection: C5VH or above Maximum sound power level: 92 dB(A), preferably lower, (at rated voltage 220/132 kV) Short circuit level 40kA
Weiterführende Details
Mit dem kostenlosen Zugang stehen Unterlagen, Fristen und Hinweise zur Einreichung strukturiert bereit.
- Kernanforderungen der Ausschreibung priorisiert aufbereitet
- Fristen, Eignungskriterien und Unterlagen in einem Ablauf
- Hinweise zur strukturierten Angebotsvorbereitung
- Passende Folgeausschreibungen automatisch entdecken
30 Tage kostenlos · keine Kreditkarte · jederzeit kündbar
Alle Vergabedetails
Auftraggeber, Lose, Beteiligte, Orte, Unterlagen und Verfahrensdaten sind bereits erfasst. Öffnen Sie einen Bereich, um die vollständigen Angaben im Workspace zu sehen.
7 Datenbereiche verfügbar
30 Tage kostenlos · keine Kreditkarte · jederzeit kündbar
Unterlagen
Freischalten50 Angaben erfasstUnterlagen · Dokumentenpaket
Auftraggeber
Freischalten3 Angaben erfasstAuftraggeber · Anschrift · Kontakt
Lose
Freischalten1 Angabe erfasstLose LOT-0000
Verfahrensdaten
Freischalten6 Angaben erfasstBekanntmachungsnummer · Verfahrensreferenz · Referenz des Auftraggebers · Verfahrensart · +2 weitere
Ausführungsorte
Freischalten2 Angaben erfasstAusführungsorte
Bieter und Auftragnehmer
Freischalten3 Angaben erfasstBieter und Auftragnehmer · Anschrift · Kontakt
Veröffentlichungsstelle
Freischalten6 Angaben erfasstVeröffentlichungsstelle · Anschrift · Kontakt
Ähnliche Bekanntmachungen
10400/132 kV Autotransformers for SLF02, PAR & ØSV
Energinet Eltransmission A/SFredericiaDelivery of three (3) 500 MVA, 400/132 kV autotransformers for substations for outdoor installation. Rated power: 500 MVA Rated voltage Ur: 400/132 kV Max. operating voltage Umax: 420 kV Frequency: 50 Hz Cooling: ONAN/ONAF Corrosion Protection: C5VH or above Maximum sound power level: 92 dB(A), preferably lower, (at rated voltage 400/132 kV)400/220 kV Autotransformers for SLF02
Energinet Eltransmission A/SFredericiaDelivery of two (2) 600 MVA, 400/220 kV autotransformer for substations for outdoor installation. Rated power: 600 MVA Rated voltage Ur: 410/235 kV Max. operating voltage Umax: 420 kV Frequency: 50 Hz Cooling: ONAN/ONAF Corrosion Protection: C5VH or above Maximum sound power level: 92 dB(A), preferably lower, (at rated voltage 410/235 kV)400/150 kV Autotransformers for NEA & NVV
Energinet Eltransmission A/SFredericiaDelivery of four (4) 600 MVA, 400/150 kV autotransformers for substations for outdoor installation. Rated power: 600 MVA Rated voltage Ur: 410/165 kV Max. operating voltage Umax: 420 kV Frequency: 50 Hz Cooling: ONAN/ONAF Corrosion Protection: C5VH or above Maximum sound power level: 92 dB(A), preferably lower, (at rated voltage 410/165 kV)Variable Shunt Reactors for outdoor installation for SLF02
Energinet Eltransmission A/SFredericiaDelivery of four (4) variable Shunt Reactor for outdoor installation at substation Idom-lund: Rated voltage Ur: 235 kV Power rating: 60-120 Mvar Regulation Range: 50 % or above Type of regulation: onload (OLTC) Cooling: ONAN Maximum sound power level: 80 dB(A), preferably lower, (at max. operating voltage 245 kV) Corrosion Protection: C5VH or above Max. operating voltage Umax: 245 kV Frequency: 50 Hz Short circuit level 40kA Magnetic characteristic: The core must be linear up to 1.5 times rated voltage.D20/CON/1189B Design, Supply and Jointing works for 220 kV oil-filled to XLPE Transition Joints for the Inchicore – Poolbeg 2nd Circuit of 220 kV circuit at Inchicore 220 kV Substation
Electricity Supply BoardDublinCON 1189B - Design, Supply and Jointing works for 220 kV oil-filled to XLPE Transition Joints for the Inchicore – Poolbeg 2nd Circuit of 220 kV circuit at Inchicore 220 kV SubstationNEA and SLF02 – Procurement of 400 kV and 132 kV cable systems
Energinet Eltransmission A/SFredericiaThe Contracting Authority wants to purchase delivery of approximately 490 km 400 kV single core cable XLPE-insulated land cable and 15 km 132 kV single core XLPE-insulated land cable, joints and terminations and installation of joints and terminations. The deliverables are divided into three lots: Lot 1 – NEA, Lot 2 - NEA and Lot 3 – SLF02. The scope of the three tendered lots are described in detail in the enclosed tender documents. For further detail regarding the purchase, reference is made to the tender documents. However please note the following: The Contracting Authority will also accept solutions with a welded aluminum sheath. In case a welded aluminum sheath is offered, the sheath is allowed to carry the full fault current without the support of a wire screen. For further information see the technical requirements c.f. doc. no. 24/13859-18. It is possible to apply for prequalification for one, two or all three lots. The application should clearly state for which lot it concerns. Subsequent tenders may be submitted for Lots the tenderer is prequalified for. If an applicant applies for prequalification for all three Lots, but does not have the capacity for all, this must be clearly stated in the application. Please note that it is not possible to include a discount for being awarded more than one lot. If the same tenderer is evaluated with the highest score for more than one lot the tenderer will be awarded more than one lot provided the tenderer fulfils the aggregated minimum requirement for economic and financial standing cf. section 2.2.1 and section 4. The tender is divided into the following lots, and the value of the contracts is expected to amount to: • Lot 1 - NEA: Expected value: EUR 42,550,000.00 • Lot 2 – NEA: Expected value: EUR 42,550,000.00 • Lot 3 – SLF02: Expected value: EUR 28,200,00.00 For further detail concerning the purchase, reference is made to the tender documents.Bestellung Sekundärtechnik 220 kV UW Wallsee-Mitterkirchen
Austrian Power Grid AGWienDurchführung der Montage Sekundärtechnik 220 kV für Umspannwerk Wallsee-Mitterkirchen (VWM)Qualification system for electrotechnical works services in 220/380 kV substations with tenders/ RFQs and execution in English language
50Hertz Transmission GmbHBerlinFrist: 18. JuliThe following work in the grid area of 50Hertz Transmission GmbH and affiliated companies is to be awarded via the qualification system: - Electrotechnical planning services - Material deliveries - Installations and assembly - Commissioning - Dismantling and disposal services Construction services and delivery of large components are provided. Voltage level from 0.4 kV and up to 380 kV. Installation services includes, amongst others: - Switchgear / bay (line, transformer, choke, coupling, etc.) - Coupling - Earthing system, lightning protection - Auxiliary systems (0.4 kV system, DC voltage system, locking and access system, system and orientation lighting, installation of relay houses) - Secondary technology (protection technology, control technology, fiber optic infrastructure, communications technology, metering)Signing of contract – the construction of 132 kV power lines Fitjar and Tysnes.
FAGNE ASHAUGESUNDFagne has entered into a contract in the procurement that was previously announced on Doffin, with reference 2026-102558. The following description was given in the original notice: Fagne plans to build a approx. 7 km long 66 (132) kV connection between Fitjar and Tysnes in Vestland County. Fagne would, thus, like to enter into a contract with a tenderer for the procurement of materials as well as the construction of the overhead power line. The power line encompasses approx. 4 km of the total route of 7 km. The procurement also includes the dismantling of the existing cable end mast in Ersvika further north at Tysnes, as well as the purchase of materials and the construction of a new cable end mast, as well as modifications to the supporting mast, including line stringing. For a more detailed description of the estimated contract start, progress and deadlines, please refer to the contract documentation chapter E. Any negotiations can be carried out in several phases/negotiation rounds, where the Contracting Authority reserves the right to reduce the number of tenders to be negotiated. A first reduction of the number of tenders can occur already before the negotiations, cf. the Utilities Regulations § 19-12 (4).LPT Bundle (Large Power Transformers)
Swissgrid AG - Asset & MaintenanceAarauFrist: 25. Jan.Die Ausschreibung beinhaltet die Berechnung, Auslegung, Konstruktion, Fertigung, Prüfung, Transport, Montage, Inbetriebsetzung, Inbetriebnahme, Dokumentation und Gewährleistung von mehreren Large Power Transformers (LPT) auf insgesamt 4 Lose wie folgt aufgeteilt. Los 1: 3 x Longitudinal & Quadrature regulated Transformer (LQT) 400 MVA, 380/220 kV LQT Soazza 1: 4 Phasen (1 Transformator-Bank + 1 Reserve-Gruppe) LQT Soazza 2: 3 Phasen (1 Transformator-Bank) LQT Tavanasa 1: 4 Phasen (1 Transformator-Bank + 1 Reserve-Gruppe) Die drei Transformatorgruppen (Phasen) einer Transformator-Bank bestehen je aus einem LRT und QRT in separaten Kesseln. Los 2: 4 x Longitudinal & Quadrature regulated Transformer (LQT) 800 MVA, 380/220 kV LQT Breite 1: 4 Phasen (1 Transformator-Bank + 1 Reserve-Gruppe) LQT Breite 2: 3 Phasen (1 Transformator-Bank) LQT Gösgen 1: 4 Phasen (1 Transformator-Bank + 1 Reserve-Gruppe) LQT Gösgen 2: 3 Phasen (1 Transformator-Bank) Die drei Transformatorgruppen (Phasen) einer Transformator-Bank bestehen je aus einem LRT und QRT in separaten Kesseln. Los 3: 2 x Phase Shifting Transformer (PST) 500 MVA, 220/220 kV PST Riddes 3: (2 Kessel, 3 polig) PST St. Triphon 1: (2 Kessel, 3 polig) PST mit zwei Kernen, Erreger- und Serie-Transformator je in separaten Kesseln Los 4: 1 x Longitudinal & Quadrature regulated Transformer (LQT) 400 MVA, 380/220 kV LQT Bickigen 1: ( 2 Kessel, 3 polig) LRT und QRT in separaten Kesseln Für die frühest möglichen Anliefertermine der einzelnen LPT konsultieren Sie bitte das Dokument 01_Verfahrensanweisung Kapitel 6.8.5 Musskriterium LPT-MK5 – Letzt möglicher Termine für „IBS abgeschlossen“ und Kapitel 6.9.6 Bewertung des Zuschlagskriteriums LPT-ZK4 – Termin „IBS abgeschlossen“ in den Ausschreibungsunterlagen. Legende: LRT → Longitudinal regulated Transformer QRT → Quadrature regulated Transformer 3 Phasen → Transformator-Bank 1 Phase → Transformator-Gruppe (LRT+QRT) LRT / QRT → Transformator Reserve-Gruppe → Reserve Phase
Häufige Fragen zu dieser Ausschreibung
- Wie kann ich mich auf diese Ausschreibung bewerben?
- Erstellen Sie ein kostenloses Konto auf Auftrag One. Danach sehen Sie alle Unterlagen, Fristen und Hinweise zur Einreichung in einem strukturierten Ablauf.
- Bis wann läuft die Angebotsfrist?
- Für diese Bekanntmachung ist aktuell keine konkrete Angebotsfrist angegeben.
- Wer ist der Auftraggeber?
- Der Auftraggeber ist Energinet Eltransmission A/S.
- Welche Unterlagen sind für den Start relevant?
- In der Regel benötigen Sie Leistungsbeschreibung, Eignungsnachweise, Fristenhinweise und ggf. Formblätter. Auf Auftrag One werden diese Punkte priorisiert dargestellt.