University College CorkCorkTED
UCC-2025-28 Supply, Delivery, Installation, Commission, Calibration, and Validation of Integrated X-ray Photoelectron Spectroscopy (XPS) System with Collocated Raman Spectroscopy Module for TNI, UCC
Tyndall National Institute, University College Cork (UCC) invites tenders for the supply, delivery, installation, commissioning, and validation of an integrated X-ray Photoelectron Spectrometer (XPS) System with Collocated Raman Spectroscopy Module, comprising two primary components: (i) XPS Module: For chemical composition and electronic...
No credit card · Instant access
Content at a glance
- Tender type:
- Tender
- Contracting authority:
- University College Cork
- Published:
- June 15, 2026
- Deadline:
- July 16, 2026
Tender description
Show full descriptionCollapse description
Tyndall National Institute, University College Cork (UCC) invites tenders for the supply, delivery, installation, commissioning, and validation of an integrated X-ray Photoelectron Spectrometer (XPS) System with Collocated Raman Spectroscopy Module, comprising two primary components: (i) XPS Module: For chemical composition and electronic structure analysis of thin films (metal oxides and 2D materials) produced by Atomic Layer Deposition (ALD) facility within Europe’s first beyond-2 nm System-on-Chip (SoC) pilot line. (ii) Raman Spectroscopy Module: For structural, vibrational, and stress analysis of the same thin-film materials (metal oxides and 2D materials) from the atomic layer processing facility. This fully integrated system will provide essential complementary surface and bulk characterisation capabilities for next-generation ALD materials research within the pilot line facility.
Further details
With free access, documents, deadlines and submission notes are available in a structured format.
- Core requirements of the tender prioritized and prepared
- Deadlines, eligibility criteria and documents in one workflow
- Guidance for structured bid preparation
- Automatically discover matching follow-up tenders
30 days free · no credit card · cancel anytime
All procurement details
Buyer, lots, participants, locations, documents, and procedure data have already been captured. Open any area to see the complete information in your workspace.
7 data areas available
30 days free · no credit card · cancel anytime
Documents
Unlock50 details capturedDocuments · Document bundle
Buyer
Unlock3 details capturedBuyer · Address · Contact
Lots
Unlock1 detail capturedLots LOT-0001
Procedure data
Unlock5 details capturedPublication number · Procedure reference · Procedure type · Contract type · +1 more
Performance locations
Unlock2 details capturedPerformance locations
Bidders and contractors
Unlock3 details capturedBidders and contractors · Address · Contact
Publisher
Unlock3 details capturedPublisher · Address · Contact
Related tenders
10Supply, Delivery, Installation, Commissioning, and Validation of an Integrated Glove Box-Linked Dual Atomic Layer Deposition (ALD) Reactor System with Collocated Ellipsometer System for Tyndall, UCC
University College CorkCorkDeadline: Jul 24Tyndall National Institute, University College Cork (UCC) invites tenders for the supply, delivery, installation, Commissioning, Calibration and Validation of an integrated Atomic Layer Deposition (ALD), Glove Box, and Ellipsometer System, compromising four main components: (i) ALD Reactor 1: Designed for the deposition of 2D dichalcogenide materials, featuring process conditions and precursor delivery systems optimised for chalcogen-based chemistries. (ii) ALD reactor 2: Configured for the deposition of metal oxide films, designed for oxygen-rich precursor processes. (iii) Glove Box Module: Provides a controlled inert atmosphere that connects both ALD reactors, enabling contamination-free sample transfer and handling. (iv) Ellipsometer: Designed to operate both in-situ and ex-situ with each ALD reactor, allowing precise thin-film thickness and optical property characterisation for process monitoring, calibration, and validation. The system must be supplied and installed by the tenderer to ensure full system integration and operational compatibility for Tyndall National Institute. Together, this integrated system will form a key capability for atomic layer processing, supporting advanced thin-film deposition and real-time characterisation for next-generation materials research.Hard X-ray Photoelectron Spectroscopy System for Energy Materials Characterization
Technische Universiteit EindhovenEindhovenDeadline: Aug 27The delivery and installation of a Hard X-ray Photoelectron Spectorscopy System for Energy Materials Characterization 1Supply, delivery, installation Lot 1-300mm Electro-Magneto-Optical Probe Station and Lot 2-Device Parameter analyser for use with 300mm Electro Magneto-Optical Probe stationTyndall National Instit UCC
University College CorkCorkDeadline: Aug 04Within the CHIPS-JU NanoIC pilot line Tyndall is developing novel materials for embedded DRAM and 3D integration for future leading-edge integrated circuits. In NanoIC, Tyndall’s flexibility into materials integration will allow for rapid, short-cycle screening to reduce the cycle time in identifying and integrating highly performing materials to carry forward into IC development. Our role is to provide agile wafer scale nanofabrication and processing beyond silicon for the integration of selected new materials – Transition Metal Dichalcogenides (TMDs) and oxide semiconductor (OSC) – and FET device architectures. The NanoIC teams at Tyndall will synthesize thin film TMDs and OSCs and will fabricate and test a wide range of materials and devices. Other activities may include compound semiconductors devices, wide band gap materials, photonic, magnetic or ferroelectric materials. The electrical properties and performance of these materials/devices are of significant importance. Consequently, a multi-function 300mm Electro-Magneto-Optical Probe Station (Lot 1) is required to study the electrical properties of these materials and devices under a range of temperature conditions. The Probe station, in combination with the Device Parameter analyser (Lot 2), will enable users to perform electrical measurements (current voltage both in DC and in pulsed mode) at different temperatures and under magnetic field or illumination as required.Durchflusszytometer für Immunpharmakologie
Universitätsklinikum Schleswig-Holstein AöRLübeckDurchflusszytometer für Immunpharmakologie Durchflusszytometer für ImmunpharmakologiePhotonische Messinstrumente
IMMS Institut für Mikroelektronik- und Mechatronik-Systeme gemeinnützige GmbHIlmenauDeadline: Jul 17Messeinheit auf der Basis eines Chassis für PXIe-Instrumente für den vollautomatisier-ten Test an photonischen Standardteststrukturen mit 4 optischen Eingängen und 12 optischen Ausgängen zum Betrieb an einem bestehenden Waferprober - siehe Leistungsbeschreibung (Anlage 01)Counterflow concrete mixer
NTNUTrondheimDeadline: Sep 03NTNU shall procure a counter-current coercive mixer for concrete with a built-in reometer to increase and lower the flow curve and tiksotropi analysis.Großmessstelle Wien AKH (Luftgütemessstelle)
Umweltbundesamt GmbHWienDeadline: Jun 22EU-Richtlinie 2024/2281 verpflichtet zur Errichtung einer Großmessstelle am AKH Wien. Beschaffung: Lieferung, Installation und Inbetriebnahme von Messgeräten für UFP (Partikelanzahlkonzentration und -größenverteilung) und BC inkl. Zusatzgeräte.Silicon Austria Labs – Chips JU: Total Reflection X-Ray Fluorescence Spectrometer (TXRF)
Silicon Austria Labs GmbHGrazThe aim of this procurement procedure was to award the contract to the best bidder identified during the procurement procedure for the supply, installation and commissioning of a Total Reflection X-Ray Fluorescence Spectrometer (TXRF) for Silicon Austria Labs GmbH.FluNQyLab_Zeitaufgelöstes Konfokal-Fluoreszenzmikroskop
Friedrich-Schiller-Universität JenaJenaDie Friedrich-Schiller-Universität Jena beabsichtigt für Forschungszwecke ein (1) vielseitiges und benutzerfreundliches zeitaufgelöstes Konfokal-Fluoreszenzmikroskop anzuschaffen, welches die optische Charakterisierung von vereinzelten sowie an optische Nanostrukturen gekoppelten Quan tenemittern ermöglicht. Das System benötigt eine entsprechend hohe räumliche Auflösung zur Abbildung nanoskaliger Strukturen, hohe Sensitivität zur Detektion einzelner Quantenemitter, sowie Zeitauflösung zur Charakterisierung der Emissionsdynamik in gekoppelten Systemen. Um die Anre gung verschiedener zu untersuchender Emittersysteme sicherzustellen, werden Anregungslaser bei verschiedenen Wellenlängen im UV- und VIS-Bereich benötigt, wobei ein schnelles Umschalten zwischen den verschiedenen Laserquellen möglich sein muss. Der Anregungslaserfokus muss dabei mit nanoskaliger Genauigkeit über die untersuchte Probe gescannt werden können und so eine zwei- bzw. prinzipiell auch dreidimensionale Bildgebung sowie Punktmessungen mit hoher Positionier genauigkeit im Nanometerbereich zu ermöglichen. Des Weiteren soll die Möglichkeit einer Weitfeldanregung für schnelle Übersichtsmessungen der räumlichen Lichtverteilung bestehen. Detektorseitig werden schnelle Detektoren mit Einzelphotonensensitivität im sichtbaren Spektralbereich benötigt. Eine leistungsfähige und schnelle Elektronik ist für Messungen der strahlenden Lebensdauer mit Zeitauflösung bis in den Picosekundenbereich essenziell. Die Anforderung, Messungen der Photonenstatistik zum Nachweis von Einzelphotonenemittern (Antibunching) oder auch von Lasing in Nanostrukturen zu ermöglichen, resultiert des Weiteren in der Notwendigkeit einer speziellen Anordnung (Hanbury-Brown-Twiss Setup) von mehreren schnellen Detektoren und der elektronischen Unterstützung von oinzidenzmessungen. Zur quantenoptischen Untersuchung von Systemen mit mehr als einem Emitter werden dabei mindestens drei in einem Detektorbaum angeordnete Detektoren benötigt. Essenziell wichtig für die geplanten Experimente sind zudem spektral aufgelöste Messungen. Das zeitaufgelöste Konfokal-Fluoreszenzmikroskop soll daher eine leistungsfähige Spektrographenerweiterung mit hoher Quanteneffizienz erhalten, welche separat beschrieben ist (siehe LV_FluNQyLab_Spektrographenerweiterung). Diese Kombination ermöglicht eine multidimensionale Analyse der Emissionseigenschaften einer großen Bandbreite von Quantenemittern in lichtemittierenden Nanostrukturen sowie auf funktionalen Substraten. Als Budget steht ein maximaler Betrag in Höhe von 520.000,00 Euro brutto zur Verfügung. Die Vergabestelle behält sich vor Angebote über diesem Wert von der Wertung auszuschließen. Liegen alle wertbaren Angebote über diesem Betrag ist die Vergabestelle berechtigt die Ausschreibung auf zuheben. Folgende Spezifikationen/Eigenschaften müssen mindestens erfüllt werden: siehe Anlage 2.Hotplate zur Temperung großflächiger Substrate für Elektronenstrahllithografie
Friedrich-Schiller-Universität JenaJenaEs soll eine halbautomatische Hotplate zur Temperung von mit Resists beschichteten Substraten für hochauflösende Elektronenstrahllithografie beschafft werden. Die Anlage dient zur definierten Pre- und Post-bake chemisch verstärkter Resists, wie bspw. FEP171, bei denen die Empfindlichkeit wesentlich durch das Temperatur Zeit Profil und die Temperatur-Homo genität bestimmt wird. Zu prozessierende Substrate umfassen u.a. 300mm-Wafer, sowie rechteckiger Glas-Substrate bis zu L x B x H = 300mm × 275mm × 15mm. Aus diesen technischen Randbedingungen ergeben sich die folgenden Anforderungen:, siehe Anlage 2.
Frequently asked questions about this tender
- How can I apply for this tender?
- Create a free account on Auftrag One. You will then see all documents, deadlines and submission notes in a structured workflow.
- What is the submission deadline?
- The submission deadline is 16. Juli 2026.
- Who is the contracting authority?
- The contracting authority is University College Cork.
- Which documents are needed to get started?
- Typically you need the service description, proof of eligibility, deadline notes and possibly form sheets. On Auftrag One these items are displayed in prioritized order.