Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ) GmbHEschbornTED
Mammography System for Turkey
Delivery of a mammography system to a hospital in Turkey including installation, commissioning and training
No credit card · Instant access
Content at a glance
- Tender type:
- Tender
- Contracting authority:
- Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ) GmbH
- Published:
- August 20, 2026
- Deadline:
- Not specified
Tender description
Delivery of a mammography system to a hospital in Turkey including installation, commissioning and training
Further details
With free access, documents, deadlines and submission notes are available in a structured format.
- Core requirements of the tender prioritized and prepared
- Deadlines, eligibility criteria and documents in one workflow
- Guidance for structured bid preparation
- Automatically discover matching follow-up tenders
30 days free · no credit card · cancel anytime
All procurement details
Buyer, lots, participants, locations, documents, and procedure data have already been captured. Open any area to see the complete information in your workspace.
7 data areas available
30 days free · no credit card · cancel anytime
Documents
Unlock50 details capturedDocuments · Document bundle
Buyer
Unlock3 details capturedBuyer · Address · Contact
Lots
Unlock1 detail capturedLots LOT-0001
Procedure data
Unlock5 details capturedPublication number · Procedure reference · Procedure type · Contract type · +1 more
Performance locations
Unlock2 details capturedPerformance locations
Bidders and contractors
Unlock3 details capturedBidders and contractors · Address · Contact
Publisher
Unlock6 details capturedPublisher · Address · Contact
Related tenders
7Procurement of a new digital 2D mammography system
PHI Health Centre Goce Delcev DelcevoDelcevoDeadline: Sep 10Procurement of a new digital 2D mammography systemProcurement of a digital 2D mammography system for the Radiology Department
PHI Health Centre KrusevoKrusevoDeadline: Sep 18Procurement of a digital 2D mammography system for the Radiology DepartmentGHA052: SOLAR BACKUP SYSTEM FOR CHPS FACILITY
IOMPhilippinesDeadline: Sep 06The solicitation is for the supply, installation, testing, and commissioning of an 8.4kWp roof-mounted solar PV backup system with 16kWh battery storage and 10kW three-phase output for the CHIPs Building and Accommodation Block in Sanyeri (Savanna Region). The contractor will provide all equipment, materials, labor, and technical services required to deliver a fully functional solar backup system, including PV panels, inverters, battery storage, mounting structures, protection devices, cabling, grounding, and security installations. The scope also includes system testing, commissioning, user training, and handover of all manuals and documentation in compliance with applicable Energy Commission and safety standardsX-ray Diffraction System for Energy Materials Characterization
Technische Universiteit EindhovenEindhovenDeadline: Oct 19The delivery and installation including warranty and maintenance of a X-ray Diffraction System for Energy Materials Characterization 1DIGITAL MAMMOGRAPHY SYSTEM 2D
Public health institution Health Center KratovoKratovoDeadline: Sep 07DIGITAL MAMMOGRAPHY SYSTEM 2D Minimum Product Characteristics No. Specification Item 1 Bucky 1.1 Motorized vertical displacement range ≥ 55 cm to ensure easy patient access in sitting, lying, and standing positions. 1.2 Two touchscreen control panel monitors for adjusting position and compression, one on each side. 1.3 Anti-scatter grid with a density ≥ 30 l/cm. 1.4 System for additional breast retraction into the acquisition field for better analysis. State the name of the offered option. 2 Generator 2.1 Built into the stand of the device due to space limitations. 2.2 High-frequency generator ≥ 100 kHz. 2.3 Maximum power ≥ 4.5 kW. 2.4 Maximum mAs value ≥ 600 mAs to obtain high-quality images even for high-density and large-sized breasts. 2.5 Maximum mA value ≥ 120 mA. 2.6 kV range: minimum range from 23 to 35 kV. 2.7 Separate exposure mode for breasts with implants. 2.8 Automatic power supply voltage compensation. 3 X-ray Tube Assembly Holder 3.1 Motorized rotation range ≥ 315°. 3.2 Isocentric motorized rotation of the C-arm so that the center of the detector always remains at the same height, reducing patient positioning time. 3.3 Heat capacity of the X-ray tube assembly holder ≥ 700 kHU. 3.4 Source-to-image receptor distance (SID) ≥ 65 cm to allow higher geometric resolution and easier patient positioning. 3.5 Manual and automatic adjustment of breast compression. 3.6 Automatic motorized collimator adjustment. 3.7 Compression plate with minimum dimensions of 18 x 23 cm. 3.8 Compression plate with minimum dimensions of 24 x 30 cm. 3.9 Display of adjusted exposure parameters: kV, mAs, compression force, and breast thickness. 3.10 Automatic exposure control. 3.11 Automatic and manual release of compression plates after imaging. 3.12 Magnification factor minimum 1.6x. 4 X-ray Tube 4.1 Minimum two focal spots; small focal spot not larger than 0.1 mm; large focal spot not larger than 0.3 mm. 4.2 Rotating anode. 4.3 Anode rotation speed ≥ 9600 rpm. 4.4 Anode heat capacity ≥ 300 kHU. 4.5 Dual motorized filters. 4.6 Automatic and manual collimation. 4.7 Automatic identification of attached compression plates and FOV adjustment. 5 Detector 5.1 New generation digital detector made of amorphous selenium or amorphous silicon with cesium iodide. 5.2 Active area size of the detector minimum 230 mm x 295 mm. 5.3 Image matrix resolution minimum 2800 x 3580 pixels. 5.4 Pixel size ≤ 85 µm. 5.5 Must be capable of operating within a minimum temperature range of 13°C to 35°C to ensure seamless system operation under local conditions. 5.6 A/D conversion minimum 16 bit. 5.7 Spatial resolution minimum 6 lp/mm. 6 Acquisition Station 6.1 Computer with minimum 8GB RAM. 6.2 Internal storage (Hard drive or SSD) minimum 1TB size. 6.3 Internal storage capacity for a minimum of 40,000 images on the acquisition workstation. 6.4 DICOM monitor with a minimum size of 23 inches and minimum resolution ≥ 2 megapixels. 6.5 Saving images to CD/DVD in DICOM format or equivalent. 6.6 Measurement of lengths and distances. 6.7 Image orientation labeling. 6.8 Zooming into the region of interest on the image. 6.9 Adding comments to the image. 6.10 Image inversion. 6.11 DICOM MPPS or equivalent. 6.12 DICOM Worklist Management or equivalent. 6.13 DICOM Print or equivalent. 6.14 Required time for image display not longer than 6 seconds. 6.15 Required time to obtain the final image not longer than 10 seconds. 6.16 Separate post-processing mode for breasts with implants. 6.17 Noise reduction tool. 6.18 Protective lead glass integrated into the control console, featuring a height-adjustable workspace to ensure greater ergonomics for the operator, providing radiation protection equivalent to a minimum of 0.5 mm Pb. 7 Diagnostic Workstation 7.1 Computer with minimum 32GB RAM. 7.2 Internal storage (Hard drive or SSD) minimum 1TB size. 7.3 Two monitors with a minimum size of 21 inches, matrix minimum 2560x2048 pixels, minimum resolution ≥ 5 megapixels. 7.4 Saving images to CD/DVD. 7.5 DICOM Print or equivalent. 7.6 Automatic alignment of images. 7.7 Paired display tool with zoom, pan, and magnification features. 7.8 Inverted tissue display without a bright background. 7.9 Tools for annotation and measurements. 7.10 Display of breasts without empty space between them. 8 Additional Options 8.1 Upgradable with hardware and software for Digital Breast Tomosynthesis (DBT). 8.2 Upgradable with a stereotactic biopsy system. ________________________________________ Terms and Conditions: ● Marketing Authorization for the medical device issued by the Agency for Medicines and Medical Devices of the Republic of North Macedonia (MALMED), in accordance with the Law on Medicines and Medical Devices. ● Equipment warranty for a minimum period of 2 (two) years, during which the economic operator is obliged to provide free servicing and free replacement of spare parts according to the recommendations of the manufacturer of the offered device. ● Mandatory submission of a completed technical specification. ● Mandatory submission of a completed manufacturer's catalog/brochure with clearly highlighted features of the offered product according to the requirements and sequential numbers in the technical specifications. ● Bids that do not contain a catalog and detailed marked characteristics will not be evaluated. ● Upon delivery of the system, the Economic Operator must perform its installation, as well as technical training for the staff of the Contracting Authority on its usage. ● Provided service center in the Republic of North Macedonia, with a service technician who has completed training for the offered model and holds a valid certificate issued by the manufacturer.Silicon Austria Labs – Chips JU: Plasma Activation system for D2W bonding
Silicon Austria Labs GmbHGrazThe aim of this procurement procedure was to award the contract to the best bidder identified during the procurement procedure for the supply, installation, commissioning and services (such as trainings) of a wafer-level plasma activation system for wafer bonding application for Silicon Austria Labs GmbH.Steam autoclaves for Akershus University Hospital.
SYKEHUSINNKJØP HFVADSØDeadline: Sep 18Sykehusinnkjøp HF shall, on behalf of the Department for Microbiology and Infection Protection at Akershus University Hospital, procure three (3) pervasive autoclaves for sterilising fluids and dry goods. The procurement includes delivery, installation, commissioning, training and the accompanying services as described in more detail in the tender documentation.
Frequently asked questions about this tender
- How can I apply for this tender?
- Create a free account on Auftrag One. You will then see all documents, deadlines and submission notes in a structured workflow.
- What is the submission deadline?
- No specific submission deadline is currently stated for this notice.
- Who is the contracting authority?
- The contracting authority is Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ) GmbH.
- Which documents are needed to get started?
- Typically you need the service description, proof of eligibility, deadline notes and possibly form sheets. On Auftrag One these items are displayed in prioritized order.