Dundalk Institute of Technology_1155DUNDALKTED
Gas Chromatography–Mass Spectrometry (GC–MS) system with a single quadrupole mass analyser
One (1) Gas Chromatography–Mass Spectrometry (GC–MS) system with a single quadrupole mass analyser suitable for undergraduate teaching and routine analytical chemistry applications. The system shall combine a gas chromatograph (GC) for separation of volatile and semi-volatile compounds with a mass spectrometer (MS) for qualitative and qua...
No credit card · Instant access
Content at a glance
- Tender type:
- Tender
- Contracting authority:
- Dundalk Institute of Technology_1155
- Published:
- September 03, 2026
- Deadline:
- Not specified
Tender description
Show full descriptionCollapse description
One (1) Gas Chromatography–Mass Spectrometry (GC–MS) system with a single quadrupole mass analyser suitable for undergraduate teaching and routine analytical chemistry applications. The system shall combine a gas chromatograph (GC) for separation of volatile and semi-volatile compounds with a mass spectrometer (MS) for qualitative and quantitative analysis. GC–MS technology enables identification, confirmation, and quantification of compounds across a wide range of matrices including environmental, food, pharmaceutical and biopharmaceutical. The system must be robust, easy to operate and suitable for undergraduate teaching laboratories, research projects and routine analytical chemistry applications
Further details
With free access, documents, deadlines and submission notes are available in a structured format.
- Core requirements of the tender prioritized and prepared
- Deadlines, eligibility criteria and documents in one workflow
- Guidance for structured bid preparation
- Automatically discover matching follow-up tenders
30 days free · no credit card · cancel anytime
All procurement details
Buyer, lots, participants, locations, documents, and procedure data have already been captured. Open any area to see the complete information in your workspace.
7 data areas available
30 days free · no credit card · cancel anytime
Documents
Unlock50 details capturedDocuments · Document bundle
Buyer
Unlock3 details capturedBuyer · Address · Contact
Lots
Unlock1 detail capturedLots LOT-0001
Procedure data
Unlock5 details capturedPublication number · Procedure reference · Procedure type · Contract type · +1 more
Performance locations
Unlock3 details capturedPerformance locations
Bidders and contractors
Unlock3 details capturedBidders and contractors · Address · Contact
Publisher
Unlock3 details capturedPublisher · Address · Contact
Related tenders
10Supplementary Request for Tenders for the supply, installation and commissioning of a Triple Quadrupole Liquid Chromatography Tandem Mass Spectrometry System (LC-MS
Bosnia and Herzegovina Railway Public Corporation (BHRPC) and the Railways of Republic of SrpskaDobojDeadline: Sep 25Supplementary Request for Tenders for the supply, installation and commissioning of a Triple Quadrupole Liquid Chromatography Tandem Mass Spectrometry System (LC-MSView CfT Workspace
Technological University Dublin (TU Dublin)Deadline: Aug 18Tenders are sought for the supply, installation, commissioning, and training for a Single Quadrupole Gas-Chromatography Mass spectrometry (GC-MS) System, with a coupled Pyrolyser Unit. The proposed GC-MS system shall be a fully programmable, high-performance instrument suitable for a broad range of analytical applications. The system must incorporate a dual column oven configuration, a single quadrupole mass spectrometry detector, and an autosampler.Analytical laboratory equipment set for the determination of microcystins and chemical monitoring, including the determination of bisphenol A, in water using liquid chromatography and mass spectrometry methods with sample preparation systems (DK 021:2015 - 38430000-8 Detectors and analyzers)
STATE INSTITUTION "LVIV OBLAST CENTER FOR DISEASES CONTROL AND PREVENTION OF THE MINISTRY OF HEALTH OF UKRAINE" (SI "LVIV OCDC MOH")LvivPurchase of a analytical laboratory equipment set for the determination of microcystins and chemical monitoring, including the determination of bisphenol A, in water using liquid chromatography and mass spectrometry methods with sample preparation systems, quantity 1 set, according to the scope of the Technical SpecificationContract for the provision of a combined High-Resolution Mass Spectrometer (HRMS) for metabolomic analysis equipped with Desorption Electrospray Ionisation (DESI) imaging capability, based on a Waters Xevo QTof/MRT platform with Desorption Electrospray Ionisation (DESI) XS with imaging capabilities.
University College CorkCork¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬¬University College Cork is seeking to procure: 1. A combined High-Resolution Mass Spectrometer (HRMS) for metabolomic analysis equipped with Desorption Electrospray Ionisation (DESI) imaging capability, based on a Waters Xevo QTof/MRT platform with Desorption Electrospray Ionisation (DESI) XS with imaging capabilities 2. A complementary triple quadrupole mass spectrometer (Waters Xevo TQ-S cronos/micro) for highly sensitive targeted quantitative metabolomics. This infrastructure is required to support a Mass Spectrometry Core Facility (MS-IMPACT) funded through the Higher Education Research Equipment Grant (HEREG). The combined platform will provide complementary capabilities spanning discovery metabolomics, structural characterisation, spatial molecular imaging, and targeted quantitative analysis. The HRMS with DESI will be used for biological, environmental, pharmaceutical, forensic, archaeological, geological and bioprocess research applications and analysis from simple and complex mixtures with the ability to simultaneously to identify known metabolites with high sensitivity, discover previously unknown molecular features, determine accurate molecular masses and elemental compositions, characterise peptides, intact proteins, glycans, and small molecules, spatially localise pharmaceuticals, metabolites and chemical entities within complex biological and non-biological samples, including microbial modifications. One of the key differentiators for the Xevo QTof/MRT platform over other instruments is the reduced sampling time which enables better consistency over the peak range – this is particularly important when sampling a surface but important in many applications. The infrastructure will support applications including: biopharmaceutical characterisation, intact protein mass analysis; peptide mapping, glycan and glycopeptide profiling, microbial fermentation studies, food and environmental metabolomics, natural product discovery, clinical biomarker discovery; pharmaceutical synthesis, process, metabolites and degradation products, forensic and contaminant analysis. A key requirement of this infrastructure is the ability to perform ambient, minimally destructive mass spectrometry imaging (MSI) ideally within one vendor integrated platform offering (hardware, software, support). The Xevo G3 QTof will be compatible for DESI XS imaging for routine comprehensive tissue imaging and for locating substrates on a range of materials. DESI enables direct analysis of compounds from surfaces under ambient conditions with little or no sample preparation, by generating charged microdroplets that extract and ionise molecules directly from the sample surface. Unlike matrix-assisted laser desorption ionisation (MALDI), DESI does not require matrix deposition, minimises chemical modification/ morphological changes in samples, reduces risk of analyte redistribution caused by matrix application; enables rapid analysis of heterogeneous samples; allows analysis under near-native conditions, facilitates analysis of diverse surfaces including tissues, microbial colonies, materials, chemical deposits, geological samples, paints/pigments and forensic samples including e.g. hair, nails , fingerprints, blood and explosive residues. DESI therefore provides a unique capability for a broad range of sample types. The DESI XS platform coupled to a high-resolution accurate mass instrument will enable: spatial metabolomics, microbial colony metabolite mapping, localisation of pharmaceutical compounds; analysis of fermentation processes; imaging of endogenous metabolites and investigation of biological and material interfaces. The imaging capability is a critical requirement of the infrastructure and represents a significant efficiency enhancement beyond conventional LC-MS analysis, allowing spatial characterisation in two dimensions. The HRMS is central to the UCC MS Core Facility and allows the simultaneous analysis of both known and ‘unknown’ compounds for high-resolution metabolomics capability to advance arrange of research programmes across the physical and life sciences. It therefore provides the required combination of sensitivity, accurate mass measurement, MS/MS capability and compatibility with DESI MS/MS imaging technology. The triple quadrupole mass spectrometer will be used in a complementary approach to the HRMS focused on targeted known metabolites across a range of food, nutrition and life science applications. While HRMS provides discovery and structural information, triple quadrupole mass spectrometry remains the benchmark technique for quantitative metabolomics, targeted biomarker validation, pharmacokinetic studies, low abundance metabolite detection; outine analytical workflows. The Xevo TQ-S cronos/micro platform provides, multiple reaction monitoring (MRM) provides high sensitivity, excellent quantitative precision high sample throughput. Applications include, but is not limited to, analysis of a range of fat- and water-soluble vitamins (as status biomarkers for population nutritional status surveillance), nucleotide sugars, amino acids, lipid mediators, microbial metabolites, pharmaceutical compounds and clinical biomarkers.Prima BT Bench Top Process Mass Spectrometer (Prima BT MS)
Aalto University Foundation srAALTOPrima BT is a process mass spectrometry platform designed for near real-time off-gas analysis from multiple bioreactors that fulfils the requirements specified in “Definition of Requirements”. It employs a magnetic sector mass spectrometer, providing high long-term stability and precision for the measurement of key gases (e.g., O₂, CO₂, N₂, Ar) across multiple streams, supporting scales from benchtop development to pilot studies. The system computes bioprocess performance indicators such as oxygen uptake rate (OUR), carbon dioxide evolution rate (CER), and respiratory quotient (RQ), providing continuous process insight without interrupting the culture. Each bioreactor stream is sampled independently through automated multiplexing, allowing customized timing, calibration factors, and data acquisition per reactor. Time-resolved gas compositions are recorded for every stream, facilitating robust mass balance calculations and volumetric mass transfer analysis. The BT MS software enables full instrument control, automated calibration and validation routines, secure data logging, and integration with laboratory and process control systems via standard protocols (e.g., OPC) for real-time monitoring, alarm management, and compliant data archival. In summary, the device is designed for comprehensive bioprocess monitoring, enabling precise, non-invasive analysis of gas exchange dynamics across multiple bioreactors simultaneously, with the magnetic sector MS providing unparalleled stability and reproducibility.Thermal desorption - gas chromatography - mass spectrometry system
Aalto University Foundation srAALTOThermal desorption - gas chromatography - mass spectrometry systemVV118 HPLC-Massenspektrometer AKH Wien
Wiener Gesundheitsverbund – Vorstandsressort Einkauf (GED EKF)WienDeadline: Sep 24Lieferung, Montage, Anwenderschulung, Technikerschulung (einmaliger Abruf) und Inbetriebnahme von 1 (einem) HPLC-Massenspektrometer am AKH WienHochauflösendes Massenspektromer
Ruhr-Universität BochumBochumLieferung eines gebrauchten Massenspektrometers Thermo Scientific Q Exactive Plus Hybrid Quadrupole-Orbitrap Mass SpectrometerExcedion Pro mit Vanquish Neo, ETD und FAIMS
Johannes Gutenberg-Universität MainzMainzBeschaffung eines hochauflösenden Massenspektrometers (Modell Excedion Pro mit Vanquish Neo, ETD und FAIMS) für strukturelle Massenspektrometrie, proteomische und lipidomische Analysen im Rahmen eines bewilligten DFG-Großgeräteantrags (INST 247/1246-1 FUGG). Die Leistung kann nur von einem bestimmten Unternehmen erbracht werden: Schutz von Ausschließlichkeitsrechten / Nichtvorhandensein von Wettbewerb aus technischen Gründen. Die Direktvergabe an die Firma Thermo Fisher Scientific ist gemäß § 14 Abs. 4 Nr. 2 VgV zwingend erforderlich, da aus technischen Gründen sowie aufgrund des Schutzes von Ausschließlichkeitsrechten kein Wettbewerb vorhanden ist. Das Modell Excedion Pro ist weltweit das einzige System, das die für die DFG-Forschungsprojekte zwingend erforderlichen Parameter in einem einzigen Gerät vereint: Begründung für die Direktvergabe gemäß § 14 Abs. 4 Nr. 2 VgV (Aus technischen Gründen sowie aufgrund des Schutzes von Ausschließlichkeitsrechten): Die Beschaffung des Massenspektrometers (Modell Excedion Pro der Firma Thermo Fisher Scientific) erfolgt im Rahmen einer Direktvergabe, da das System weltweit als einziges die zwingend erforderlichen Parameter für die bewilligten DFG-Forschungsprojekte (INST 247/1246-1 FUGG) in einem Gerät vereint. Ein Wettbewerb ist aus folgenden technischen und patentrechtlichen Gründen nicht vorhanden: Zwingende technische Alleinstellungsmerkmale: Massenauflösung: Für die Analyse komplexer Probengemische (z. B. neuronale Synapsen, Peptid-Lipid-Konjugate) ist eine Auflösung von > 400.000 (bei m/z 200) mit einer Massengenauigkeit von > 0,001 m/z unverzichtbar. Nur so lassen sich Fehlbestimmungen und erhöhte Falsch-Positiv-Raten beim Datenbankabgleich sicher vermeiden. Kombinierte Fragmentierungsmethoden: Die Identifizierung der Reaktionsmechanismen bei Protein-Lipid-Quervernetzungen erfordert zwingend die simultane Anwendung von kollisions- und elektronentransferbasierter Fragmentierung (HCD, ETD und EThcD) innerhalb derselben Messu167 - ICP-QQQ System
RWTH Aachen UniversityAachen1 x ICP-QQQ System um hochsensitive Spuren- und Ultraspurenanalysen in komplexen Proben-matrices reproduzierbar und qualitätsgesichert durchführen zu können
Frequently asked questions about this tender
- How can I apply for this tender?
- Create a free account on Auftrag One. You will then see all documents, deadlines and submission notes in a structured workflow.
- What is the submission deadline?
- No specific submission deadline is currently stated for this notice.
- Who is the contracting authority?
- The contracting authority is Dundalk Institute of Technology_1155.
- Which documents are needed to get started?
- Typically you need the service description, proof of eligibility, deadline notes and possibly form sheets. On Auftrag One these items are displayed in prioritized order.