Energinet Eltransmission A/SFredericiaTED
220/132 kV Autotransformers for SLF02
Delivery of three (3) 500 MVA, 220/132 kV autotransformers for substations for out-door installation. Rated power: 500 MVA Rated voltage Ur: 220/132 kV Max. operating voltage Umax: 245 kV Frequency: 50 Hz Cooling: ONAN/ONAF Corrosion Protection: C5VH or above Maximum sound power level: 92 dB(A), preferably lower, (at rated voltage 220/132...
Grid Infrastructure
No credit card · Instant access
Content at a glance
- Tender type:
- Tender
- Contracting authority:
- Energinet Eltransmission A/S
- Published:
- August 09, 2026
- Deadline:
- Not specified
- Topic:
- Grid Infrastructure
Tender description
Delivery of three (3) 500 MVA, 220/132 kV autotransformers for substations for out-door installation. Rated power: 500 MVA Rated voltage Ur: 220/132 kV Max. operating voltage Umax: 245 kV Frequency: 50 Hz Cooling: ONAN/ONAF Corrosion Protection: C5VH or above Maximum sound power level: 92 dB(A), preferably lower, (at rated voltage 220/132 kV) Short circuit level 40kA
Further details
With free access, documents, deadlines and submission notes are available in a structured format.
- Core requirements of the tender prioritized and prepared
- Deadlines, eligibility criteria and documents in one workflow
- Guidance for structured bid preparation
- Automatically discover matching follow-up tenders
30 days free · no credit card · cancel anytime
All procurement details
Buyer, lots, participants, locations, documents, and procedure data have already been captured. Open any area to see the complete information in your workspace.
7 data areas available
30 days free · no credit card · cancel anytime
Documents
Unlock50 details capturedDocuments · Document bundle
Buyer
Unlock3 details capturedBuyer · Address · Contact
Lots
Unlock1 detail capturedLots LOT-0000
Procedure data
Unlock6 details capturedPublication number · Procedure reference · Buyer reference · Procedure type · +2 more
Performance locations
Unlock2 details capturedPerformance locations
Bidders and contractors
Unlock3 details capturedBidders and contractors · Address · Contact
Publisher
Unlock6 details capturedPublisher · Address · Contact
Related tenders
10400/132 kV Autotransformers for SLF02, PAR & ØSV
Energinet Eltransmission A/SFredericiaDelivery of three (3) 500 MVA, 400/132 kV autotransformers for substations for outdoor installation. Rated power: 500 MVA Rated voltage Ur: 400/132 kV Max. operating voltage Umax: 420 kV Frequency: 50 Hz Cooling: ONAN/ONAF Corrosion Protection: C5VH or above Maximum sound power level: 92 dB(A), preferably lower, (at rated voltage 400/132 kV)400/220 kV Autotransformers for SLF02
Energinet Eltransmission A/SFredericiaDelivery of two (2) 600 MVA, 400/220 kV autotransformer for substations for outdoor installation. Rated power: 600 MVA Rated voltage Ur: 410/235 kV Max. operating voltage Umax: 420 kV Frequency: 50 Hz Cooling: ONAN/ONAF Corrosion Protection: C5VH or above Maximum sound power level: 92 dB(A), preferably lower, (at rated voltage 410/235 kV)400/150 kV Autotransformers for NEA & NVV
Energinet Eltransmission A/SFredericiaDelivery of four (4) 600 MVA, 400/150 kV autotransformers for substations for outdoor installation. Rated power: 600 MVA Rated voltage Ur: 410/165 kV Max. operating voltage Umax: 420 kV Frequency: 50 Hz Cooling: ONAN/ONAF Corrosion Protection: C5VH or above Maximum sound power level: 92 dB(A), preferably lower, (at rated voltage 410/165 kV)Variable Shunt Reactors for outdoor installation for SLF02
Energinet Eltransmission A/SFredericiaDelivery of four (4) variable Shunt Reactor for outdoor installation at substation Idom-lund: Rated voltage Ur: 235 kV Power rating: 60-120 Mvar Regulation Range: 50 % or above Type of regulation: onload (OLTC) Cooling: ONAN Maximum sound power level: 80 dB(A), preferably lower, (at max. operating voltage 245 kV) Corrosion Protection: C5VH or above Max. operating voltage Umax: 245 kV Frequency: 50 Hz Short circuit level 40kA Magnetic characteristic: The core must be linear up to 1.5 times rated voltage.D20/CON/1189B Design, Supply and Jointing works for 220 kV oil-filled to XLPE Transition Joints for the Inchicore – Poolbeg 2nd Circuit of 220 kV circuit at Inchicore 220 kV Substation
Electricity Supply BoardDublinCON 1189B - Design, Supply and Jointing works for 220 kV oil-filled to XLPE Transition Joints for the Inchicore – Poolbeg 2nd Circuit of 220 kV circuit at Inchicore 220 kV SubstationNEA and SLF02 – Procurement of 400 kV and 132 kV cable systems
Energinet Eltransmission A/SFredericiaThe Contracting Authority wants to purchase delivery of approximately 490 km 400 kV single core cable XLPE-insulated land cable and 15 km 132 kV single core XLPE-insulated land cable, joints and terminations and installation of joints and terminations. The deliverables are divided into three lots: Lot 1 – NEA, Lot 2 - NEA and Lot 3 – SLF02. The scope of the three tendered lots are described in detail in the enclosed tender documents. For further detail regarding the purchase, reference is made to the tender documents. However please note the following: The Contracting Authority will also accept solutions with a welded aluminum sheath. In case a welded aluminum sheath is offered, the sheath is allowed to carry the full fault current without the support of a wire screen. For further information see the technical requirements c.f. doc. no. 24/13859-18. It is possible to apply for prequalification for one, two or all three lots. The application should clearly state for which lot it concerns. Subsequent tenders may be submitted for Lots the tenderer is prequalified for. If an applicant applies for prequalification for all three Lots, but does not have the capacity for all, this must be clearly stated in the application. Please note that it is not possible to include a discount for being awarded more than one lot. If the same tenderer is evaluated with the highest score for more than one lot the tenderer will be awarded more than one lot provided the tenderer fulfils the aggregated minimum requirement for economic and financial standing cf. section 2.2.1 and section 4. The tender is divided into the following lots, and the value of the contracts is expected to amount to: • Lot 1 - NEA: Expected value: EUR 42,550,000.00 • Lot 2 – NEA: Expected value: EUR 42,550,000.00 • Lot 3 – SLF02: Expected value: EUR 28,200,00.00 For further detail concerning the purchase, reference is made to the tender documents.Bestellung Sekundärtechnik 220 kV UW Wallsee-Mitterkirchen
Austrian Power Grid AGWienDurchführung der Montage Sekundärtechnik 220 kV für Umspannwerk Wallsee-Mitterkirchen (VWM)Qualification system for electrotechnical works services in 220/380 kV substations with tenders/ RFQs and execution in English language
50Hertz Transmission GmbHBerlinDeadline: Jul 18The following work in the grid area of 50Hertz Transmission GmbH and affiliated companies is to be awarded via the qualification system: - Electrotechnical planning services - Material deliveries - Installations and assembly - Commissioning - Dismantling and disposal services Construction services and delivery of large components are provided. Voltage level from 0.4 kV and up to 380 kV. Installation services includes, amongst others: - Switchgear / bay (line, transformer, choke, coupling, etc.) - Coupling - Earthing system, lightning protection - Auxiliary systems (0.4 kV system, DC voltage system, locking and access system, system and orientation lighting, installation of relay houses) - Secondary technology (protection technology, control technology, fiber optic infrastructure, communications technology, metering)Signing of contract – the construction of 132 kV power lines Fitjar and Tysnes.
FAGNE ASHAUGESUNDFagne has entered into a contract in the procurement that was previously announced on Doffin, with reference 2026-102558. The following description was given in the original notice: Fagne plans to build a approx. 7 km long 66 (132) kV connection between Fitjar and Tysnes in Vestland County. Fagne would, thus, like to enter into a contract with a tenderer for the procurement of materials as well as the construction of the overhead power line. The power line encompasses approx. 4 km of the total route of 7 km. The procurement also includes the dismantling of the existing cable end mast in Ersvika further north at Tysnes, as well as the purchase of materials and the construction of a new cable end mast, as well as modifications to the supporting mast, including line stringing. For a more detailed description of the estimated contract start, progress and deadlines, please refer to the contract documentation chapter E. Any negotiations can be carried out in several phases/negotiation rounds, where the Contracting Authority reserves the right to reduce the number of tenders to be negotiated. A first reduction of the number of tenders can occur already before the negotiations, cf. the Utilities Regulations § 19-12 (4).LPT Bundle (Large Power Transformers)
Swissgrid AG - Asset & MaintenanceAarauDeadline: Jan 25Die Ausschreibung beinhaltet die Berechnung, Auslegung, Konstruktion, Fertigung, Prüfung, Transport, Montage, Inbetriebsetzung, Inbetriebnahme, Dokumentation und Gewährleistung von mehreren Large Power Transformers (LPT) auf insgesamt 4 Lose wie folgt aufgeteilt. Los 1: 3 x Longitudinal & Quadrature regulated Transformer (LQT) 400 MVA, 380/220 kV LQT Soazza 1: 4 Phasen (1 Transformator-Bank + 1 Reserve-Gruppe) LQT Soazza 2: 3 Phasen (1 Transformator-Bank) LQT Tavanasa 1: 4 Phasen (1 Transformator-Bank + 1 Reserve-Gruppe) Die drei Transformatorgruppen (Phasen) einer Transformator-Bank bestehen je aus einem LRT und QRT in separaten Kesseln. Los 2: 4 x Longitudinal & Quadrature regulated Transformer (LQT) 800 MVA, 380/220 kV LQT Breite 1: 4 Phasen (1 Transformator-Bank + 1 Reserve-Gruppe) LQT Breite 2: 3 Phasen (1 Transformator-Bank) LQT Gösgen 1: 4 Phasen (1 Transformator-Bank + 1 Reserve-Gruppe) LQT Gösgen 2: 3 Phasen (1 Transformator-Bank) Die drei Transformatorgruppen (Phasen) einer Transformator-Bank bestehen je aus einem LRT und QRT in separaten Kesseln. Los 3: 2 x Phase Shifting Transformer (PST) 500 MVA, 220/220 kV PST Riddes 3: (2 Kessel, 3 polig) PST St. Triphon 1: (2 Kessel, 3 polig) PST mit zwei Kernen, Erreger- und Serie-Transformator je in separaten Kesseln Los 4: 1 x Longitudinal & Quadrature regulated Transformer (LQT) 400 MVA, 380/220 kV LQT Bickigen 1: ( 2 Kessel, 3 polig) LRT und QRT in separaten Kesseln Für die frühest möglichen Anliefertermine der einzelnen LPT konsultieren Sie bitte das Dokument 01_Verfahrensanweisung Kapitel 6.8.5 Musskriterium LPT-MK5 – Letzt möglicher Termine für „IBS abgeschlossen“ und Kapitel 6.9.6 Bewertung des Zuschlagskriteriums LPT-ZK4 – Termin „IBS abgeschlossen“ in den Ausschreibungsunterlagen. Legende: LRT → Longitudinal regulated Transformer QRT → Quadrature regulated Transformer 3 Phasen → Transformator-Bank 1 Phase → Transformator-Gruppe (LRT+QRT) LRT / QRT → Transformator Reserve-Gruppe → Reserve Phase
Frequently asked questions about this tender
- How can I apply for this tender?
- Create a free account on Auftrag One. You will then see all documents, deadlines and submission notes in a structured workflow.
- What is the submission deadline?
- No specific submission deadline is currently stated for this notice.
- Who is the contracting authority?
- The contracting authority is Energinet Eltransmission A/S.
- Which documents are needed to get started?
- Typically you need the service description, proof of eligibility, deadline notes and possibly form sheets. On Auftrag One these items are displayed in prioritized order.